2
1 Preliminary note
You will find instructions, technical data, approvals and further information using
the QR code on the unit / packaging or at
1.1 Symbols used
Requirement
Instructions
Reaction, result
[...]
Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note
2 Intended use
The unit detects ferromagnetic metals (FE metals) without contact and indicates
their presence by a switching signal.
3 Mounting
3.1 MFH
M12x1-6H
12,4
10 H7
Rz
6,3
15°
≥10
7
11
R
1,5
90°
max
The unit can be adjusted to the piston rod via the insertion depth.