Capacitive sensor
KI0058
11
The modified basic teach empty state is also recommended if it has not been possible to carry out a
basic teach empty state (e.g. if the sensor is set up on a full tank).
The modified basic teach empty state can be repeated at any time, an adjustment teach full state
already carried out is not affected.
u
Empty the tank until the level is below the sensing face of the device.
w
For NO the LED goes out, for NC the LED lights.
Set the device as normally open (output closes when the tank is full):
u
Press the button [OUT OFF] for at least 6 seconds.
w
While pressing the pushbutton the LED first flashes slowly, after 6 seconds more quickly. After
releasing the pushbutton, the LED goes out.
Set the device as normally closed (output opens when the tank is full):
u
Press the button [OUT ON] for at least 6 seconds.
w
While pressing the pushbutton the LED first flashes slowly, after 6 seconds more quickly. After
releasing the pushbutton, the LED lights continuously.
7.4 Switching delays
u
Press the buttons [OUT ON] and [OUT OFF] at the same time for at least 20 seconds.
w
After 20 seconds the LED flashes. The device is now in the programming mode. The switching
output is enabled during programming.
u
Press the button [OUT ON] or [OUT OFF] to set the delay time.
•
Each push of the button [OUT OFF ] sets the next level down.
•
Each push of the button [OUT ON] sets the next level up.
The set level is indicated by the number of LED flashes.
The following levels can be set:
Step
Delay time in min
LED display (flashing)
1
15
1x
2
30
2x
3
45
3x
4
60
4x
5
0
5x
u
Press the buttons [OUT ON] and [OUT OFF] at the same time for at least 2 seconds or wait for 20
seconds.
w
The device applies the setting and goes back to the operating mode.
7.5 Lock / unlock
The device can be locked electronically to prevent unintentional settings. Factory setting: not locked.
Lock / unlock:
u
Press the buttons [OUT ON] and [OUT OFF] at the same time for 10 s.
w
Acknowledgement: LED state changes for a short time (the lit LED goes out briefly or the LED
which is not lit lights briefly).
If the unit does not react, it may be locked.