Installation Instructions
Temperature transmitter
TA3333TA3337
704559 / 01
12 / 2012
UK
Page 1: ...Installation Instructions Temperature transmitter TA3333 TA3337 704559 01 12 2012 UK ...
Page 2: ...it into an analog output signal 4 20 mA Measuring range TA3333 17 8 148 9 C 0 300 F TA3337 0 100 C 32 212 F Measuring element Pt1000 to DIN EN 60751 class A Temperature resistance 110 115 120 125 130 135 140 145 150 C 40 80 120 160 200 240 min 0 155 Maximum operation time depending on the medium temperature ...
Page 3: ...5 mm 0 6 inch Tighten firmly Tightening torque max 25 Nm 18 ft lbs 3 Electrical connection The unit must be connected by a suitably qualified electrician The national and international regulations for the installation of electrical equipment must be observed Voltage supply to EN50178 SELV PELV Disconnect power Connecting the unit as follows L 3 4 2 1 L 3 1 4 2 n c n c n c not connected ...