Operating instructions 

Programming and display unit

PP2001 

11450559 / 00

 

05 / 2010

UK

Summary of Contents for Efector 500 PP2001

Page 1: ...Operating instructions Programming and display unit PP2001 11450559 00 05 2010 UK ...

Page 2: ... 5 7 1 Online operation 6 8 Operating and display elements 7 9 Menu 8 9 1 Menu structure 8 10 Operation 9 10 1 Connection of a sensor initialisation 9 10 2 Setting the sensor parameters 10 10 3 Copying the parameter set of a sensor 12 10 4 Changing a stored parameter set 13 10 5 Transferring a parameter set to other sensors 14 10 6 Remote display remote evaluation 15 11 Scale drawing 16 12 Technic...

Page 3: ...any restrictions If the operating instructions or the technical data are not adhered to personal injury and or damage to property can occur Check the compatibility of the product materials Technical data with the media to be measured in all applications For the scope of validity cULus The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the fo...

Page 4: ...dications in the operation instructions of the sensor PP2001 is suitable for mobile use as well as for permanent installation 6 Installation Sensors can be read and parameterised before installation and set up or dur ing operation If you change parameters during operation the operating principle of the production plant will be influenced Ensure that there will be no malfunctions in your plant 5 Fu...

Page 5: ...g 10 3 10 5 Changing a stored parameter set 10 4 Remote display remote evaluation 10 6 6 Installation For stationary operation two types of installation are possible Fixing with mounting clamp Fixing with mounting bracket A mounting clamp to be ordered sepa rately as accessories order no E10077 A mounting bracket Diameter of the bore hole 18 5 20 mm Loosen the threaded sleeve B Insert the unit in ...

Page 6: ...the connector from the sensor and screw it to PP2001 plug A Connect the sensor to PP2001 socket B via the supplied connection cable Switch on the supply voltage If you change parameters during operation the operating principle of the production plant will be influenced Ensure that there will be no malfunctions in your plant ...

Page 7: ...system pressure in MPa LED 5 LED 1 green indication of the system pressure in mmHg LED 6 green indication of the pressure system in PSI LED 6 LED 1 green indication of the pressure system in inHg LED 7 yellow output 2 is switched LED 8 yellow output 1 is switched 9 Alphanumeric display 4 digits System pressure is displayed Parameters parameter values and action points are displayed 10 Set button S...

Page 8: ...8 9 Menu 9 1 Menu structure 1 sensor specific parameters depending on the connected sensor 2 action points of the PP2001 ...

Page 9: ... not support the parameter setting and editing functions Only the evaluating function Transmission of the output signals 10 6 and the copy functions 10 3 and 10 5 are supported If the sensor is disconnected a running display indicates the type of the stored data set Then EDIT is displayed If another sensor is connected the initialisation step 1 starts again Error messages E COM Input output error ...

Page 10: ...ly by pressing the button once or continuously by keeping the button pressed Numerical values are incremented continuously For reducing the value let the dis play move to the maximum setting value Then the cycle starts again at the minimum setting value 4 Acknowledgement of the parameter value Press Mode Enter briefly SEND is briefly displayed then the parameter designation The new setting value i...

Page 11: ...m menu level 1 to menu level 2 Press Mode Enter until EF is displayed Press Set briefly The first parameter of the sub menu is displayed here HI Locking unlocking The sensor can be locked electronically to prevent unintentional settings Make sure that the unit is in the normal operating mode Press Mode Enter Set for 10 s Loc is displayed During operation Loc is briefly displayed if you try to chan...

Page 12: ...ly The unit goes into the operation mode the sensor type and then the current measured value are displayed Error messages when carrying out the COPY action E COM Input output error communication error data transfer disturbed E INI Communication error or data error initialisation support of the sensor not possible E SEN Sensor type error the sensor type is not supported E STO Error when storing the...

Page 13: ...ayed here SP1 4 Carry out the parameter setting 10 2 This operation can only be carried out if no sensor is connected If for the data set stored in PP2001 only the copy functions are supported the editing function is not active After step 2 Mode Enter pressed briefly TYPE and the sensor type are displayed running display Timeout If no button is pressed for 15 s the unit returns to step 2 A paramet...

Page 14: ...opying process Press Mode Enter when SEND is displayed The unit goes into the operation mode the sensor type and then the current measured value are displayed In case of communication via IO Link with a low baud rate the operation can take one minute or more Error messages when carrying out the SEND action E COM Input output error communication error data transfer disturbed E INI Communication err...

Page 15: ...ers are displayed one after the other Press Set briefly the corresponding parameter value is displayed for about 15 s After another 15 s the unit returns to the Run mode Error messages SC1 Short circuit in OUT1 of PP2001 SC2 Short circuit in OUT2 of the connected sensor signalled via the communication interface to PP2001 SC Short circuit in both outputs The output concerned is switched off as long...

Page 16: ... 11 Scale drawing Dimensions in mm 1 4 digit alphanumeric display 2 LEDs display unit switching status 3 programming button 4 connection for voltage supply and output signals 5 connection for sensor 6 nut ...

Page 17: ... 200 Housing materials stainless steel 316L 1 4404 PC Copolymer PBT Pocan FPM Viton Protection IP 67 Protection class III Insulation resistance MΩ 100 500 V DC Shock resistance g DIN IEC 68 2 27 50 g 11 ms Vibration resistance g DIN IEC 68 2 6 20 g 10 2000 Hz Operating temperature C 25 80 Storage temperature C 40 100 EMC EN 61000 4 2 ESD 4 kV contact discharge 8 kV air discharge EN 61000 4 3 HF ra...