1 Preliminary note
1.1 Symbols used
►
Instruction
>
Reaction, result
→
Cross-reference
Important note
Non-compliance can result in malfunctions or interference.
2 Functions and features
The through-beam sensor detects objects and materials without contact and
indicates their presence by a switching signal.
Range: (
→
type label).
3 Installation
1
1
LED
1:
Install the receiver (OGE3xx) and secure it to a bracket.
►
Align the transmitter (OGS3xx) to the receiver and secure it in the same way.
►
Maximum range only with accurate alignment.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electri-
►
cal equipment must be adhered to.
Ensure voltage supply to EN 50178.
►
Disconnect power.
►
Connect the unit as follows:
►