Functions and features

In conjunction with a prismatic reflector or reflective tape the retro-reflective 
sensor detects objects and materials without contact and indicates their presence 
by a switched signal.
Range (r): see type label.

Installation

1

LED

Place prismatic reflector or reflective tape behind the object to be detected. Align 
the photocell and fasten it to a mounting bracket.
Maximum range is only achieved with precise alignment.

Electrical connection

Disconnect power before connecting the unit as follows:

L+

L

1
4
3

Operation

Check the safe functioning of the sensor.

Units with dark-on mode (OGP-DPKG): The output is switched / the yellow LED 
is lit when an object is present.
Units with light-on mode (OGP-HPKG): The output is switched / the yellow LED 
is lit when no object is present.