7  Operation

 

► Check whether the unit operates correctly.

 

> The green LED is lit when the sensor is ready for operation.

 

> Dark-on mode: the output is switched / the yellow LED is lit when an object is 

detected.

 

> Light-on mode: the output is switched / the yellow LED is lit when no object is 

detected.

8  IO-Link

8.1  General information

This unit has an IO-Link communication interface which requires an IO-Link-

capable module (IO-Link master) for operation. 
The IO-Link interface enables direct access to the sensor values and parameters 

and provides the possibility to set the parameters of the unit during operation.
In addition communication is possible via a point-to-point connection with a USB 

adapter cable.
You will find more detailed information about IO-Link at www.ifm.com/uk/io-link.

8.2  Device-specific information

You will find the IODDs necessary for the configuration of the IO-Link unit and 

detailed information about sensor values, diagnostic information and parameters 

in the overview table at www.ifm.com/uk/io-link.

8.3  Parameter setting tools

You will find all necessary information about the required IO-Link hardware and 

software (e.g. ifm LINERECORDER SENSOR ZGS210) at www.ifm.com/uk/io-link.

Summary of Contents for Efector 200 O6E3

Page 1: ...Operating instructions Through beam sensor O6E3 O6S3 O6E3IO 00 01 2015 UK ...

Page 2: ...result in malfunctions or interference 2 Functions and features The through beam sensor detects objects and materials without contact and indicates their presence by a switching signal 3 Installation Transmitter Receiver Install the receiver O6E and secure it to a bracket Align the transmitter O6S to the receiver and fix it Maximum range only with accurate alignment ...

Page 3: ...Selector output function Receiver 4 1 Stability indication The green LED on the receiver is lit when the supply voltage is applied and there is sufficient excess gain Under these conditions the sensor receives a stable signal stable signal switch point stable signal Light on mode LED green on off off on LED yellow on on off off Dark on mode LED green on off off on LED yellow off off on on ...

Page 4: ...adhered to Ensure voltage supply to EN 50178 Disconnect power Connect the unit as follows 5 1 Transmitter Connector M12 pigtail Cable 1 3 L L Connector M8 3 pin Connector M8 4 pin 1 3 L L 2 1 4 3 1 3 L L Core colours BN brown BU blue BK black 5 2 Receiver 5 2 1 PNP Connector M12 pigtail Cable Connector M8 3 pin Connector M8 4 pin 2 1 4 3 Core colours BN brown BU blue BK black ...

Page 5: ... 3 Core colours BN brown BU blue BK black 6 Settings 6 1 Set the output function D L Setting D dark on mode Setting L light on mode Receiver 6 2 Set the sensitivity Increase sensitivity turn the setting screw of the potenti ometer clockwise Decrease sensitivity turn the setting screw of the potenti ometer anti clockwise Receiver ...

Page 6: ...or values and parameters and provides the possibility to set the parameters of the unit during operation In addition communication is possible via a point to point connection with a USB adapter cable You will find more detailed information about IO Link at www ifm com uk io link 8 2 Device specific information You will find the IODDs necessary for the configuration of the IO Link unit and detailed...

Page 7: ... any solvents or cleaning agents which could damage the plastic parts After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations Faulty sensors must only be repaired by the manufacturer Technical data and further information at unter www ifm com ...