Settings
6
Sensitivity setting
6.1
The sensor is to switch when the object is detected
1
Position the object.
►
Press [OUT on] for 2 s.
►
The sensitivity is set to the object. The LED flashes.
>
2
Remove the object.
►
Press [OUT off].
►
The sensitivity is set without object.
>
The LED goes out. The setting operation is completed.
>
The sensor is not to switch when the object is detected
Position the object (see figure 1) and press [OUT off].
►
Remove the object (see figure 2) and press [OUT on].
►
The settings can also be carried out first without object (step 1) and then with
object (step 2).
Setting of maximum sensitivity
6.2
Align the sensor so that no light is reflected.
►
The sensor is to switch when the object is detected
First press [OUT on], then [OUT off].
►
The sensor is to switch when the object is not detected