CAN message (J1939)

Description

Value

KeyPad_J1939_I Drive_4 

Byte address: Byte 1, bit 6

Status key 4

0 = key not pressed

 

1 = key pressed

KeyPad_J1939_I Drive_5 

Byte address: Byte 2, bit 0

Status key 5

0 = key not pressed

 

1 = key pressed

KeyPad_J1939_I Drive_6 

Byte address: Byte 2, bit 2

Status key 6

0 = key not pressed

 

1 = key pressed

8.2  CAN messages for the rotary button 

CAN identifier: 0x10FF6487(default)

J1939 PGN: 0xFF64
J1939 priority: 0x4

CAN message (J1939)

Description

Value

KeyPad_J1939_I Drive_EncVal 

Byte address: Byte 3

Number of steps that the rotary 

button has been turned since the 

last query

0���24 

24 = one full turn 

KeyPad_J1939_I Drive_EncDir 

byte address: Byte 3, bit 5

Rotational direction

0 =  clockwise

 

1 = anti-clockwise

KeyPad_J1939_I Drive_Enter 

Byte address: Byte 3, bit 6

Rotary button pressed

0 = rotary button not pressed

 

1 = rotary button pressed

KeyPad_J1939_I Drive_Left 

Byte address: Byte 4, bit 0

Rotary button tilted to the left

0 = rotary button not tilted

 

1 = rotary button tilted

KeyPad_J1939_I Drive_Right 

Byte address: Byte 4, bit 2

Rotary button tilted to the right

0 = rotary button not tilted

 

1 = rotary button tilted

KeyPad_J1939_I Drive_Up 

Byte address: Byte 4, bit 4

Rotary button tilted upwards

0 = rotary button not tilted

 

1 = rotary button tilted

KeyPad_J1939_I Drive_Down 

Byte address: Byte 4, bit 6

Rotary button tilted downwards

0 = rotary button not tilted

 

1 = rotary button tilted

8.3  CAN messages for the illumination

All CAN messages for the illumination have a data length of 8 bytes and a value 

range of 0���255�

CAN message (J1939)

Byte 

1

Byte 

2

Byte 

3

Byte 

4

Byte 

5

Byte 

6

Byte 

7

Byte 

8

LIGHT_J1939_BUTTON1_2_

INTENSITY

CAN ID: 0x18FF7587(default)

 

J1939 PGN: 0xFF75 

J1939 priority: 0x06

key 1

key 2

R

G

B

R

G

B

FF

FF

Summary of Contents for ecomatPanel CR1300

Page 1: ...Operating instructions ecomatPanel CR1300 CR1301 80296590 00 08 2020 UK ...

Page 2: ...tallation instructions 6 5 2 1 Location for mounting accessories 6 6 Electrical connection 6 6 1 Connection accessories 6 6 2 General wiring information 6 6 2 1 Cover all unused connectors 7 6 3 Fuses 7 6 4 Operating voltage and CAN interface 7 7 Operating and display elements 8 8 Operation 8 8 1 CAN messages for the keys 8 8 2 CAN messages for the rotary button 9 8 3 CAN messages for the illumina...

Page 3: ...sult Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result NOTE Warning of damage to property ...

Page 4: ...ng up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose 3 Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur In case of malfunctions of ...

Page 5: ... approved for safety related tasks in the field of operator protection Only use the unit within the limits of the technical data 4 Function 4 1 Overview of the common characteristics Rotary button with turn tilt and push function 6 programmable function keys with RGB background illumination for night design Plastic housing for panel mounting and surface mounting in the cabin CAN interface with SAE...

Page 6: ...tions 5 2 1 Location for mounting accessories The back of the unit has been prepared for fixing the mounting accessories 84 8 78 Location for mounting accessories back of the unit Usable M6 thread depth 18 mm 6 Electrical connection 6 1 Connection accessories You can find more information about the available accessories at www ifm com 6 2 General wiring information 1 1 Supply CAN 4 pin Tyco MQS co...

Page 7: ...ith a strain relief 6 2 1 Cover all unused connectors Moisture penetrating through unused or unprotected connectors may destroy the unit Cover unused connectors with protective caps 6 3 Fuses To protect the unit use fuses for the operating voltages Designation Potential Connector 1 Fuse Operating voltage 9 32 V DC Pin 4 max 2 A Terminal designation to DIN 72552 6 4 Operating voltage and CAN interf...

Page 8: ...e keys cyclically every 30 ms Dynamic addressing via J1939 possible The display elements keep the status of the last message 8 1 CAN messages for the keys CAN identifier 0x10FF6487 default J1939 PGN 0xFF64 J1939 priority 0x4 CAN message J1939 Description Value KeyPad_J1939_I Drive_1 Byte address Byte 1 bit 0 Status key 1 0 key not pressed 1 key pressed KeyPad_J1939_I Drive_2 Byte address Byte 1 bi...

Page 9: ...er Byte address Byte 3 bit 6 Rotary button pressed 0 rotary button not pressed 1 rotary button pressed KeyPad_J1939_I Drive_Left Byte address Byte 4 bit 0 Rotary button tilted to the left 0 rotary button not tilted 1 rotary button tilted KeyPad_J1939_I Drive_Right Byte address Byte 4 bit 2 Rotary button tilted to the right 0 rotary button not tilted 1 rotary button tilted KeyPad_J1939_I Drive_Up B...

Page 10: ...1939_CORONA3_4_ INTENSITY only CR1301 CAN ID 0x18FF7987 default J1939 PGN 0xFF79 J1939 priority 0x06 LED segment 3 LED segment 4 R G B R G B FF FF Example Trigger key 1 and key 2 to light orange CAN message J1939 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Example CAN message ID 16x18FF7587 key 1 key 2 R G B R G B FF FF ifm orange 255 R 110 G 0 B 255 110 0 255 110 0 255 255 9 Maintenan...

Page 11: ...UK ecomatPanel CR1300 CR1301 11 10 Approvals standards Test standards regulations the EU declaration of conformity and approvals can be found at www ifm com ...

Reviews: