ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
Configurations
Operating elements - functions
87
5.9
Operating elements - functions
10160
The following tasks have to be solved in the visualisations of the application:
- jump to the visualisation pages,
- change parameter values in the input fields,
- confirm messages.
To do so, the
ecomat
mobile
PDM devices provide a number of operating elements.
For the devices of the PDM families you can assign functions to certain operating elements or signals.
To do so, there are several ways which can also be combined in some cases:
Method
Can be used for the following devices
PRG PDM_MAIN_MAPPER
- PDM360: CR1050, CR1051, CR1060
- PDM360compact: CR1052, CR1053, CR1055, CR1056
System variables in the PLC configuration
chapter
Use edit controls
(
→
- PDM360NG: CR108n, CR9042
CoDeSys dialogue [Element Configuration]
all devices
Library
ifm_PDM_INPUT_Vxxyyzz.Lib
(contains function blocks to manage input fields)
chapter
Edit input fields in the visualisation
(
→
page
- BasicDisplay: CR0451
- PDM360: CR1050, CR1051, CR1060
- PDM360compact: CR1052, CR1053, CR1055, CR1056
- PDM360NG: CR108n, CR9042
- PDM360smart: CR1070, CR1071
User-specific functions and POUs
all devices
5.9.1
Use edit controls
10158
Available for the following devices:
- PDM360NG: CR108n, CR9042
Groups of keys
chapter
Numbering of the operating elements
(
→
page
)
System variable
chapter
System flags
(
→
page
)
ifm
provides the application programmer with "edit controls". You can link functions to operating
elements using system variables in the PLC configuration.
For normal mode:
MD_KEYx_y
STRING(31) Assignment of key y in the group of keys x (set as default)
For the edit mode:
ME_KEYx_y
STRING(31) Assignment of key y in the group of keys x (edit mode)
As STRING a key must be assigned a keyword (
next chapter).