361
WRITE_PARAMETER_WORD
3413
Unit type = function block (FB)
Executeable from the CoDeSys version 2.3.6.1. Don't use it for older projects!
Contained in the library:
ifm_PDM_FILE_Vxxyyzz.LIB
Available for the following devices:
- PDM360: CR1050, CR1051, CR1060
- PDM360compact: CR1052, CR1053, CR1055, CR1056
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
3521
WRITE_PARAMETER_WORD writes datasets of type WORD to the indicated text file.
Saving the data in the text file is right-aligned, e.g.:
Value
Saved as
1 00001
123 00123
12345 12345