4 Installation

4.1 Mounting accessories

The unit is supplied without mounting accessories.

Depending on the intended installation location and type of mounting, the following mounting
accessories are available:

EC0730, installation kit for panel mounting

EC1410...EC1414, RAM® mount system for surface mounting

More information about available accessories at 

www.ifm.com

4.2 General installation instructions

The following applies to all types of mounting:

The responsibility for the compliance with the requirements concerning mounting of the device
in the application with regard to shock, vibration, acceleration and weight lies with the system
architect.

ATTENTION

Impact stress on display screen

w

Damage possible

w

Protection rating and electrical protection might be impaired

w

Risk of injury possible

u

If necessary, the system creator must take external measures to protect the device
depending on the requirements of the corresponding application.

u

Replace damaged devices, otherwise the technical data and safety will be impaired.

On the back, the pressure compensation element, the service cover and the connector areas
are to be protected by taking external measures, if necessary.

4.2.1 Location for mounting accessories

The back of the device has been prepared for fixing the mounting accessories.

Summary of Contents for ecomatDisplay CR1152

Page 1: ...Operating instructions Process and dialogue module ecomatDisplay CR1152 11427142 00 03 2022 GB...

Page 2: ...ce mounting with RAM mount system 11 4 4 1 Mounting steps 12 4 5 Other installation types 12 5 Electrical connection 13 5 1 Wiring 13 5 2 Connection accessories 13 5 3 Connection technology 13 5 4 Gen...

Page 3: ...eaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTEN...

Page 4: ...uring the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Intend...

Page 5: ...ether with the Linux operating system they form a universal platform for networking and communication with other CAN devices networks or PCs By default the device is not intended for direct connection...

Page 6: ...tton 1 Ethernet interfaces 1 CAN interfaces 4 ifm plug play CAN based 1 USB 2 0 interfaces 1 Analogue video inputs 2 Digital inputs BL 2 Digital outputs 2 5 A 2 Line In Speaker output 1 Headphone outp...

Page 7: ...in the application with regard to shock vibration acceleration and weight lies with the system architect ATTENTION Impact stress on display screen w Damage possible w Protection rating and electrical...

Page 8: ...ic materials may damage the device u Do not use any sealing materials in the area around the pressure compensation elements 4 2 2 Light sensor and status LED The device is equipped with a light sensor...

Page 9: ...system creator When installing the device in a control cabinet the following requirements concerning fire protection apply If installed according to the information given in 4 3 the device itself comp...

Page 10: ...ion kit Fig 2 Fixing profile of the installation kit Fig 3 Dialogue module with mounted installation kit Use the fixing profile of the mounting kit only together with a suitable spacer and the damping...

Page 11: ...with surface finishing on a zinc nickel basis with thick film passivation and sealing 2 3 4 5 6 7 1 Fig 6 Mounting principle 1 M5 hexagon nuts 2 fixing profile 3 panel cut out 4 spacer 5 damping stri...

Page 12: ...unting plate ball head of the selected RAM mount component on suitable surface according to RAM mount indications 38 1 5 56 62 6 Fig 10 Mounting plate with ball head 38 1 30 5 3 Fig 11 Hole dimensions...

Page 13: ...ION Reverse polarity protection not ensured in case of power supply SELV PELV on VBB30 and VBB0 Reverse polarity protection is only ensured in case of supply via the on board system via a battery if t...

Page 14: ...er The ingress resistance of cables that users have cut to length must be guaranteed u Use twisted pair cables for the CAN IFM connection The CAN bus is internally protected against short circuit to V...

Page 15: ...otive spade type fuses are recommended Designation Connector 1 Operating voltage Nominal value fuse Required triggering characteristics VBB15 Pin 119 8 16 V DC and 16 32 V DC Ignition starter switch 3...

Page 16: ...ength depends for example on the bus topology the selected operating mode 10 100 Mbits s or the quality of the connectors u Use screened connector housings and connect the screen of the Ethernet cable...

Page 17: ...e module The length B considerably influences the quality of the USB data transmission B Connection USB connector USB device u Use a connection cable with the designation Full Speed High Speed USB con...

Page 18: ...the dialogue module w Shortly after the unit is switched on the start image appears for approx 10 to 15 seconds During this time the booting process is running in the background After booting the App...

Page 19: ...ce temperature must not exceed the maximum permissible value Technical data www ifm com The value provided by the internal temperature sensor can e g be used for the following actions Reduction of the...

Page 20: ...er before opening it u Remove the service cover on the back of the device width across flats 13 mm or u Protect inside of device sealing areas and sealing of the service cover from soiling and humidit...

Page 21: ...re recommended 7 3 Cleaning the housing surface u Disconnect the device u Clean the device from dirt using a soft chemically untreated and dry cloth u In case of severe soiling use a damp cloth 7 4 Re...

Reviews: