199
ifm
Device Manual SmartSPS AC14 with EtherNet/IP interface (AC1421, AC1422), Firmware 3.1.2
2015-11-30
Appendix
Fieldbus EtherNet/IP
>
Diagnosis - system diagnosis
12657
System diagnosis:
Offset
Word no.
bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
1
-
-
-
-
-
-
-
-
-
-
-
-
PS
GI
OT
ISE
Legend:
Alarm
Description
ISE
Internal System Error Interner K6-Systemfehler
OT
over temperature: temperature inside the device has exceeded the permissible max. temperature value
GI
gateway inactive: the gateway mode was deactivated
PS
PLC stop: The controller was stopped