Address assignment and I/O operating modes
>
Inputs: operating modes
21001
Possible configuration combinations (where permissible) are created by adding the configuration
values.
= this configuration value is default
Inputs
Possible operating mode
Set with …
FB input
Value
dec
hex
ANALOG0...7 IN_DIGITAL_H
plus
--
1
01
IN_CURRENT
0…20 000 µA
ANALOG0_4_MODE
--
4
04
IN_VOLTAGE10
0…10 000 mV
ANALOG1_5_MODE
--
8
08
IN_VOLTAGE32
0…32 000 mV
ANALOG2_6_MODE
--
16
10
IN_RATIO32
0…1 000 ‰
ANALOG3_7_MODE
--
32
20
IN_DIAGNOSTIC
with IN_DIGITAL_H
--
64
40
IN00…07
IN_DIGITAL_H
plus
INxx_MODE
--
1
01
IN_DIAGNOSTIC
with IN_DIGITAL_H
INxx_MODE
--
64
40
IN08…11
IN_DIGITAL_H
plus
INxx_MODE
--
1
01
IN_DIAGNOSTIC
with IN_DIGITAL_H
INxx_MODE
--
64
40
IN_FAST
for interrupt FBs
INxx_MODE
--
128
80
Frequency measurement
0…30 000 Hz
FB FREQUENCY
→ FB description
Period measurement
0.1...5 000 Hz
FB PERIOD
→ FB description
Period duration and ratio
measurement
0.1...5 000 Hz
FB PERIOD_RATIO
→ FB description
Counter
0…50 Hz
FB FAST_COUNT
→ FB description
Detect encoder values
0…30 000 Hz
FB INC_ENCODER
→ FB description
IN12…15
IN_DIGITAL_H
plus
INxx_MODE
--
1
01
IN_DIGITAL_L
minus
INxx_MODE
--
2
02
IN_DIAGNOSTIC
with IN_DIGITAL_H
INxx_MODE
--
64
40
Set operating modes with the following function block:
FAST_COUNT
(→ page
Counter block for fast input pulses
FREQUENCY
(→ page
Measures the frequency of the signal arriving at the selected channel
INC_ENCODER
(→ page
Up/down counter function for the evaluation of encoders
PERIOD
(→ page
Measures the frequency and the cycle period (cycle time) in [µs] at the indicated channel
PERIOD_RATIO
(→ page
Measures the frequency and the cycle period (cycle time) in [µs] during the indicated periods at
the indicated channel. In addition, the mark-to-space ratio is indicated in [‰].