Page 2: ...Application specific tag 14 9 1 2 Function tag 14 9 1 3 Location tag 14 9 2 Parameter 14 9 2 1 Operating mode 15 9 2 2 LED Intensity 15 9 2 3 Buzzer Intensity 15 9 2 4 User preference color Bank 1 LED...

Page 3: ...pprovals and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross re...

Page 4: ...roduct and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its int...

Page 5: ...ling The LEDs LED segments and the audible warning device can be switched on and off individually The unit is not suited for environments with particular requirements on mechanical stability e g shock...

Page 6: ...peration of the unit via the IO Link interface requires an IO Link master With a PC suitable IO Link software and an IO Link adapter cable communication is possible while the system is not in operatio...

Page 7: ...vertical surface loosen the screw in the base turn the upper part of the base by 180 and tighten the screw again Attach the base to the fixture overlapping marks on base and fixture and turn clockwise...

Page 8: ...of electrical equipment Voltage supply according to SELV PELV The IO Link port must be connected according to the IO Link specification u Disconnect power u Connect the cable with the M12 connector of...

Page 9: ...t 2 with 4 RGB LEDs as factory setting number and size of the LED segment can be configured 3 Segment 3 with 4 RGB LEDs as factory setting number and size of the LED segment can be configured 4 Segmen...

Page 10: ...ght tower 10 7 2 Level Meter Mode 2 3 1 1 LED 20 as factory setting direction of movement of LED control can be configured 2 LED 1 as factory setting direction of movement of LED control can be config...

Page 11: ...LEDs can be divided into a maximum of 5 LED segments Space between the segments The lowest LED in each LED segment can be switched off Colour per LED segment off red green orange blue violet turquois...

Page 12: ...or the LEDs Direction of movement from bottom to top or from top to bottom Level thresholds per LED a maximum of 20 thresholds between 0 and 100 in ascending order When the threshold is exceeded the c...

Page 13: ...is sent in the process data byte 0 bit 1 2 the current display of the segments LEDs is overwritten with the selected colour combination Bank 1 2 or 3 For example in Level Meter Mode a warning message...

Page 14: ...IO Link master to a parameter setting software u Set the port of the master to the IO Link operating mode u Connect the device to a free port of the IO Link master w The unit switches to IO Link mode...

Page 15: ...User preference color Bank 2 LED x Colour definition of the 20 LEDs in user specific combination 2 For each LED 1 of 21 colours or the switched off state can be configured Factory setting for all LED...

Page 16: ...e in Signal Light Mode 9 2 10 Segment appearance Segment x Setting of the flashing frequency for this segment Permanently on factory setting for segment 1 5 Flashing slow Flashing medium Flashing fast...

Page 17: ...associated parameters are kept Only the top LED The colour and flashing frequency of the LED with the currently highest exceeded threshold are kept from the associated parameters For all LEDs with lo...

Page 18: ...blue 5 8 turquoise 9 12 green 13 16 orange 17 20 red This parameter is only available in Level Meter Mode 9 2 16 LED appearance LED x Setting of the flashing frequency for this LED Permanently on fac...

Page 19: ...the voltage supply u Clean the unit from dirt using a soft chemically untreated and dry micro fibre cloth The operation of the unit is maintenance free Only the manufacturer is allowed to repair the...