7
UK
of the base by 180 ° and tighten the screw again� Attach the base to the fixture
(overlapping marks on base and fixture) and turn clockwise by approx� 10 ° to
fix it�
►
Insert the cable through the fixture and, if necessary, the base and connect the
socket with the M12 connector in the signal lamp� Tightening torque max� 1
Nm�
►
Attach the signal lamp to the fixture or the base (overlapping marks) and turn
clockwise by approx� 10 ° to fix it�
Observe the maximum tightening torque of the connection cable�
Integrated seals at the bottom of the fixture and in the base as well as
O-rings at the fixture and base prevent ingress of moisture�
More information about available accessories at www�ifm�com
5 Electrical connection
The unit must be connected by a qualified electrician�
The national and international regulations for the installation of electrical
equipment must be adhered to�
Voltage supply according to SELV, PELV
►
Disconnect power�
►
Connect the unit�
5.1 IO-Link connection
The IO-Link port must be connected according to the IO-Link specification�