background image

5

UK

2.2  Radio equipment

In general, radio equipment must not be used in the vicinity of petrol stations, fuel 

depots, chemical plants or blasting operations�

 

Do not transport and store any flammable gases, liquids or explosive 

substances near the unit�

2.3  Interference of electronic and medical devices

Operation can affect the function of electronic devices that are not correctly 

shielded�

 

Disconnect the device in the vicinity of medical equipment�

 

Contact the manufacturer of the corresponding device in case of any 

interference�

3  Functions and features

In combination with the IO-Link master the read/write head DTI430/DTI431 is used 

for non-contact reading and writing of RFID tags that conform to the system� 
The data is available as process data at the IO-Link interface�

4  Functions

4.1  Operating principle

The ID tags are operated passively, i�e� without battery� The energy required for 

operation is supplied by the read/write head�
The physical principle of the energy transfer is based on inductive coupling� The 

integrated antenna coil in the read/write head generates a magnetic field which 

partly penetrates the antenna coil of the ID tag� A voltage is generated by induction 

that supplies the data carrier with energy�

Summary of Contents for DTI430

Page 1: ...Installation Instructions RF identification system Read write head DTI430 DTI431 80270386 00 01 2018 UK ...

Page 2: ...Installation 6 5 1 General installation instructions 6 5 2 Notes on ID tag mounting 6 5 3 Avoiding interference 7 5 4 Mechanical design 7 5 5 Fixing 7 5 6 Mounting distances 8 5 6 1 DTI430 8 5 6 2 DTI431 8 5 7 Positioning of the ID tags 9 5 7 1 DTI430 9 5 7 2 DTI431 9 6 Electrical connection 10 6 1 Wiring 10 7 Display elements 11 8 Operation 11 9 Dimensions 12 9 1 DTI430 12 9 2 DTI431 12 10 Techni...

Page 3: ...3 UK 12 Approvals standards 13 12 1 Radio approvals 13 12 1 1 Overview 13 12 1 2 Europe 13 12 1 3 EC declaration of conformity 13 ...

Page 4: ...ions 2 1 General Observe the operating instructions Non observance of the instructions operation which is not in accordance with use as prescribed below wrong installation or incorrect handling can affect the safety of operators and machinery The installation and connection must comply with the applicable national and international standards Responsibility lies with the person installing the devic...

Page 5: ... any interference 3 Functions and features In combination with the IO Link master the read write head DTI430 DTI431 is used for non contact reading and writing of RFID tags that conform to the system The data is available as process data at the IO Link interface 4 Functions 4 1 Operating principle The ID tags are operated passively i e without battery The energy required for operation is supplied ...

Page 6: ...d write head in metal reduces the read write distance The immediate vicinity of powerful HF emission sources such as welding transformers or converters can affect operation of the read write heads Information on the available mounting accessories is available on our website at www ifm com 5 2 Notes on ID tag mounting If the ID tags are mounted in on metal the read write distance is reduced For pos...

Page 7: ...eld with a frequency of 13 56 MHz To avoid interference of the data communication no other devices generating interference emission in this frequency band must be operated in the vicinity Such devices are for example frequency converters and switched mode power supplies 5 4 Mechanical design 1 Sensing face 5 5 Fixing Fix the device using the supplied nuts M30 flush DTI430 non flush DTI431 ...

Page 8: ...ting distances 5 6 1 DTI430 Operating mode Distance side A Distance front B For reading and writing 50 mm 100 mm 5 6 2 DTI431 Operating mode Distance side A Distance front B For reading and writing 120 mm 160 mm ...

Page 9: ...ID tag Type metal plastics E80370 20 mm 20 mm E80371 25 mm 30 mm All indications apply to static read write operations 5 7 2 DTI431 D Align the ID tag on the antenna central axis Distance read write head D ID tag Type metal plastics E80370 35 mm 35 mm E80371 45 mm 45 mm All indications apply to static read write operations ...

Page 10: ...III PC III The electric supply must only be made via PELV SELV circuits Disconnect power before connecting the unit 6 1 Wiring Connect the unit to the IO Link master via the M12 connector Voltage is supplied via the IO Link master 4 1 3 L 1 3 4 L IO Link A selection of sockets is available on our website at www ifm com ...

Page 11: ...ow ON permanently ID tag detected ON pulse ID tag read written successfully FLASHING QUICKLY Error when reading writing on ID tag OFF No ID tag in the field or faulty ID tag in the field or invalid ID tag in the field Green yellow FLASHING ALTERNATELY Device fault 8 Operation The read write head is configured via the IO Link master You can find more information about the operation in the manual ww...

Page 12: ...12 9 Dimensions 9 1 DTI430 39 29 M30x1 5 37 50 M12 x1 5 36 1 5 9 2 DTI431 39 18 M30x1 5 37 50 M12 x1 5 15 36 10 Technical data The data sheets are available on our website at www ifm com ...

Page 13: ... national environmental regulations 12 Approvals standards 12 1 Radio approvals 12 1 1 Overview The overview of the approval status of a unit is available on our website at www ifm com 12 1 2 Europe Use in all EU countries 12 1 3 EC declaration of conformity ifm electronic gmbh hereby declares that the DTI430 DTI431 radio system corresponds to the directive 2014 53 EU You can find the EC declarati...