![IFM DTI424 Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/ifm/dti424/dti424_operating-instructions-manual_3863664010.webp)
DTI424 DTI425
10
DTI425
Operating mode
Distance side (A)
Distance front (B)
For reading and writing
≥ 90 mm
≥ 180 mm
6.6 Positioning of the ID tags
The read/write heads are marked with an antenna symbol on the sensing face. It designates the
middle of the integrated antenna coil and has to correspond with the middle of the ID tag.
u
Align the axes of the RFID device and the ID tag in the same way.
For installation in or on metal use the ID tags provided for this purpose.
Position the ID tag in the area of the sensing face. When doing so, the angle of aperture and the
operating distance must be adhered to (→ Data sheet of the device).
DTI424
D
Fig. 5: Position the ID tag
u
Align the ID tag on the central axis of the antenna of the unit.
ID tag
Type
Distance read/write head (D) in plastic
E80371
16 mm
The indications in the table apply to static read/write operations.