DTI420 DTI421
23
Command
value
Data
0 to 27
Block
counter
Error
value
Status bit
"Cmd
End"
Status bit
"Cmd
Start"
Controller ac-
knowledges re-
ceipt of the data
0x03
Data
0x01
0x00
0
1
Device sets
more data and
terminates read-
ing
0x03
Data
0x02
0x00
1
1
Controller ac-
knowledges re-
ceipt of the data
0x03
Data
0x02
0x00
1
1
Controller with-
draws com-
mand value
0x03
Data
0x02
0x00
1
1
Device carries
out preset com-
mand
0x00
UID
0x00
0x00
0
0
Tab. 4: Process data input
10.5.2 Example unsuccessful reading of data
Example shows that reading of the data was unsuccessful.
Command
value
Address
Length
Data
0 to 27
Block
counter
Status bit
"Cmd
Start"
Preset com-
mand
0x00
0x0000
0x0000
0x00
0x00
0
Controller sets
command (read
35 bytes from
address 0x12)
0x03
0x0012
0x0023
0x00
0x00
1
Device acknowl-
edges com-
mand
0x03
0x0012
0x0023
0x00
0x00
1
Device sets first
byte of the data
0x03
0x0012
0x0023
0x00
0x00
1
Controller ac-
knowledges re-
ceipt of the data
0x03
0x0012
0x0023
0x00
0x01
1
Unit sets error
value
0x03
0x0012
0x0023
0x00
0x01
1
(ID tag not
available)
0x00
0x0000
0x0000
0x00
0x00
0
Controller with-
draws com-
mand value
0x00
0x0000
0x0000
0x00
0x00
0
Tab. 5: Process data output
Command
value
Data
0 to 27
Block
counter
Error
value
Status bit
"Cmd
End"
Status bit
"Cmd
Start"
Preset com-
mand
0x00
UID
0x00
0x00
0
0