background image

11

UK

6.5.2  Installation with mounting device E80336

The mounting device is used to mount the device to a clamp� The following clamps 

can be used:
•  E21110 with a rod diameter of 12 mm
•  E20795 with a rod diameter of 14 mm
•  E21109 with a rod diameter of 14 mm

Fig� 7: Installation with mounting device E80336

6.5.3  Installation with fixing bars E80337

Fig� 8: Installation with fixing bars E80337

 

Fix the device with fixing screws to the designated location�

Summary of Contents for DTE801

Page 1: ...Installation instructions RFID compact unit DTE801 DTE802 DTE803 DTE804 80279577 00 03 2019 UK...

Page 2: ...on instructions 8 6 2 Notes on ID tag mounting 8 6 3 Avoiding interference 9 6 4 Mechanical design 9 6 5 Installation options 9 6 5 1 Installation with angle bracket E80335 10 6 5 2 Installation with...

Page 3: ...s DTE802 20 8 4 1 LED Mod module status 20 8 4 2 LED Net network status 21 8 5 LED indicators DT803 22 8 5 1 RUN LED 22 8 5 2 LED ERR 22 8 6 LED indicators DTE804 23 8 6 1 LED SF 23 8 6 2 LED BF 23 9...

Page 4: ...roduced and used without the consent of ifm electronic gmbh All product names pictures companies or other brands used on our pages are the property of the respective rights owners 2 Safety instruction...

Page 5: ...outside petrol stations fuel depots chemical plants or blasting operations Do not transport and store any flammable gases liquids or explosive substances near the device Contact the manufacturer of t...

Page 6: ...tionality HTTP server M12 twisted pair 4 Items supplied DTE80x RFID compact unit Installation instructions The device is supplied without installation and connection accessories In the event of incomp...

Page 7: ...3 Overview DTE802 Art no Function Type designation Operating frequency Type Typ transmitter power DTE802 RFID compact unit DTRUHFE HLRWEIUS04 865 868 MHz rectangular 23 dBm ERP 200 mW Fig 2 Overview...

Page 8: ...inimum distance of 10 cm Disconnect the device in the vicinity of medical equipment 6 1 General installation instructions Devices installed next to each other interfere if they are not configured corr...

Page 9: ...f the data communication no other RFID UHF devices generating interference emission in this frequency band must be operated in its vicinity Observe the notes on installation when several RFID UHF devi...

Page 10: ...10 6 5 1 Installation with angle bracket E80335 Fig 6 Installation with angle bracket E80335...

Page 11: ...ng clamps can be used E21110 with a rod diameter of 12 mm E20795 with a rod diameter of 14 mm E21109 with a rod diameter of 14 mm Fig 7 Installation with mounting device E80336 6 5 3 Installation with...

Page 12: ...B Reading and writing at 100 transmitter power simultaneous operation 6 0 m 10 0 m Reading and writing at 100 transmitter power alternating operation 0 3 m 0 3 m 6 7 Positioning of the ID tags D Alig...

Page 13: ...P rating indicated in the data sheet is only guaranteed if the M12 connectors are firmly screwed The device can be damaged by insufficiently tightened M12 connectors Screw the M12 connector to the dev...

Page 14: ...Connection 1 TD 2 RD 3 TD 4 RD Fig 12 Pin connection fieldbus connection 7 2 1 Factory setting of the Ethernet parameters The following values are preset at the factory Parameter Factory setting IP a...

Page 15: ...must be connected to an earth potential free from external voltage 7 3 1 Mounting plate When the device is fixed on a mounting plate the connection is made via one of the four mounting bolts on the ba...

Page 16: ...s Remove all cable connections from the device Insert an electrically conductive bridge between pin 2 and pin 4 on the process connection voltage supply PWR Connect the device to the voltage supply Th...

Page 17: ...on flashing quickly ID tag read written incorrectly If the ID tag has a high receive signal strength all LEDs of the signal bar are on configurable The maximum receive signal strength depends on the...

Page 18: ...2 4 Special device LED indicators LED Status Note PWR LED green on LEDs of signal bar yellow flashing at 8 Hz device is in the service mode emergency system started A firmware update is necessary and...

Page 19: ...on off error at device level temperature flashing flashing self test starting phase of the device 8 3 2 LED BF LED red LED green Status Note off off no voltage supply check the voltage supply off fla...

Page 20: ...Check the parameter setting of the configuration assembly off on normal operation Connection to the EtherNet IP scanner is established The device is configured The data transfer is running flashing o...

Page 21: ...d Check the configuration of the device via EtherNet IP scanner off on connection exists At least one EtherNet IP connection to the device was established flashing off timeout of the connection A time...

Page 22: ...error EtherCAT communication of the device is in working condition flickering Booting error detected INIT status reached but error indicator bit is set to 1 in AL status register reboot the device fl...

Page 23: ...hing flashing self test starting phase of the device 8 6 2 LED BF LED red LED green Status Note off off no voltage supply check the voltage supply off flashing connection to host controller exists the...

Page 24: ...ally friendly way in accordance with the applicable national regulations Keep the device free from soiling Use glass cleaner as cleaning agent Do not open the device 11 Approvals standards 11 1 Radio...

Page 25: ...25 UK 12 Scale drawing 64 12 5 88 12 4 50 113 113 120 34 34 M12x1...

Reviews: