6
• DTE601: communication with the control level via PROFINET IO,
• DTE602: communication with the control level via EtherNet/IP,
• DTE604: communication with the control level via EtherNet TCP/IP,
• DTE605: communication with the control level via EtherNet IoT protocol,
• can be configured via a web server�
Example applications:
• material flow control in production lines
• warehouse management by the automatic detection of stored products
• tank management, order picking or product tracking
The device may only be used under the operating conditions specified in
the data sheet�
3.1 Configuration via Ethernet interface
• 10 Mbps and 100 Mbps
• TCP/IP - Transport Control Protocol / Internet Protocol
• IT functionality: HTTP server
• M12, twisted pair
4 Items supplied
• DTE60x RFID compact unit
• Installation instructions
The device is supplied without installation and connection accessories�
In the event of incomplete or damaged items supplied, please contact ifm
electronic�
5 Function
5.1 Operating principle
The ID tags are operated passively, i�e� without battery� The energy required for
operation is supplied by the RFID compact unit�
The physical principle of the energy transfer is based on inductive coupling� The
integrated antenna coil in the RFID compact unit generates a magnetic field