12

6.1  Maximum length of the connection cables

With IO-Link communication on the master side: 20 m.

All cables must be provided with a strain relief approx. 200 mm behind the 

connectors.

7  Operation 

The device provides the output signals according to the process data set via IO-

Link.

8  Parameters

8.1  Parameters via IO-Link
8.1.1  Application-specific tag

Customer-specific application description, max. 32 characters long. 

Value: “ *** ” / can be freely defined by the customer

8.1.2  Plant identification code

Customer-specific plant identification code, max. 32 characters. 

Value: “ *** ” / can be freely defined by the customer

8.1.3  Location identification code

Customer-specific location identification code, max. 32 characters. 

Value: “ *** ” / can be freely defined by the customer

9  Parameter setting

During parameter setting, the device remains in the operating mode. 

It continues its monitoring functions with the existing parameters until the 

parameter setting has been completed.

Summary of Contents for DP1223

Page 1: ...Operating instructions Converter IO Link 2 x 0 10 V DP1223 80272879 00 02 2020 UK...

Page 2: ...elements 8 4 1 LEDs 8 4 1 1 Visualisation of the voltage value at the output 9 5 Installation 9 6 Electrical connection 10 6 1 Maximum length of the connection cables 12 7 Operation 12 8 Parameters 12...

Page 3: ...3 UK 13 1 Maintenance 15 13 2 Cleaning the housing surface 15 13 3 Repair 15 13 4 Disposal 15 This document is the original instructions...

Page 4: ...uttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used WARNING Warning of serious personal injur...

Page 5: ...tem Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any...

Page 6: ...r device with analogue input 0 10 V It is not suited for environments with particular requirements on mechanical stability e g shock vibration The device has two analogue voltage outputs The device is...

Page 7: ...out the required IO Link hardware and software at www ifm com gb io link 3 2 0 10 V 24 V DC 1 Fieldbus 4 5 6 Application example with IO Link master 1 Analogue actuator 2 Converter IO Link 2 x 0 10 V...

Page 8: ...V flashing 5 Hz Short circuit or overload at the output Power green on Voltage supply OK Device in operating mode flashing 5 Hz Device supply undervoltage off Voltage supply off II OUT2 yellow on Anal...

Page 9: ...e in the application Depending on the operating conditions the device is also to be protected against mechanical stress e g shock or vibration If required the device can be fixed with a mounting clip...

Page 10: ...rotected via IO Link master Pin 4 2 A Required tripping characteristic of the fuses Tfuse 120 s at max 6 25 A fire protection Alternatively supply the device via a limited energy circuit according to...

Page 11: ...nect other devices to the converter Also see application examples 3 Functions and features Tighten the M12 connectors firmly to ensure the protection rating Protection rating 11 Technical data Connect...

Page 12: ...plication description max 32 characters long Value can be freely defined by the customer 8 1 2 Plant identification code Customer specific plant identification code max 32 characters Value can be free...

Page 13: ...13 UK 10 Scale drawing Original Scale Drawing MTD EPS Source Product Scale Drawing Frame Size 80 mm x 49 5 mm P_MZ_e200_0100 31 24 30 M12x1 M12x1 63 1 31 24 30 M12x1 M12x1 63 1 Dimensions mm...

Page 14: ...relative humidity 90 31 C linearly decreasing to 50 40 C non condensing Maximum operating altitude m 4000 above sea level Connectors M12 connector 4 pole M12 socket 5 pole With threaded M12 connector...

Page 15: ...pply voltage 6 and 11 II flashing 5 Hz Short circuit or overload at the output Check correct connection cables and connections at the output 6 13 Maintenance repair and disposal 13 1 Maintenance The u...