6.1 LED display
Status
LED status
In the measuring range
yellow (permanently on)
Outside the measuring range (UL)
yellow (flashing) 2 Hz mark-to-space
ratio 1:1
Outside the measuring range (OL)
yellow (flashing) 2 Hz mark-to-space
ratio 1:1
After power-on in the IO-Link mode => "NO
DATA“ (PDV = +32764)
If no process data value is measured or max�
120 s
yellow (flashing) 2 Hz mark-to-space
ratio 1:1
6.2 Setting parameters via IO-Link
Parameter
Description
Setting range
Application Specific
Tag
Application Specific Tag
max� 32 bytes
default = ***
P-n
Output polarity for the
switching outputs
PNP / NPN
default = PNP
SSC1 Param SP1
Setpoint 1
5���24000 pulses/min
default = 5 pulses/min
SSC1 Param SP2
Setpoint 2
3���21600 pulses/min
default = 3 pulses/min
SSC1 Config Logic
Setpoint logic / State for
target detected
NO / NC
default = NO
SSC1 Config Mode
Setpoint mode
single point / window / two-point
mode
default = single point mode
SSC1 Config Hyst
Setpoint hysteresis
10%
SSC1
switch-on delay
Switching signal channel 1,
Switch-On delay
0���60000 ms (100 ms steps)
default = 0 ms
SSC1
switch-off delay
Switching signal channel 1,
Switch-Off delay,
0���60000 ms (100 ms steps)
default = 0 ms