46
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
System description
Hardware description
>
Output type OUT PWM-n-BRIDGE-A
23094
n = current rating
Example: n = 25
I
max
= 2.5 A
Binary output or
analogue output with pulse width modulation (PWM), optionally current-controlled (PWM
I
)
or bridge output (via PWM)
Block diagram
OUT PWM-n-A
OUT#### = connection of PWM output no. ####
(CR) = device
(1) = measured value (analogue)
(2) = measured value (binary)
Configure input
→ Chapter System configuration
Possible operating modes:
Binary output CSO (B
H
)
Binary output CSI (B
L
)
analogue output CSO with pulse width modulation (PWM
H
), current controlled (PWM
I
)
analogue output CSI with pulse width modulation (PWM
L
)
analogue output CSO with pulse width modulation, current-controlled (PWM
I
)
Pair of outputs as bridge with pulse width modulation (PWM)
Setting and measurement via
:
FB
Output
(
) for binary output
FB
PWM1000
(
) for PWM
FB
CurrentControl
(
) for current control (PWM
I
)
FB
HBridge
(
) for bridge output