123
ifm
Programming Manual ecomatController/60-1 (CR711S) Operating System V2.5.0.n
2017-12-19
ifm function libraries
ifmFastInput.library
>
10.4.8
MODE_INC_ENCODER (ENUM)
23271
Name
Description
Possible values
MOTE_INC_ENCODER Operating mode of the input
UNCHANGED
Setting remains unchanged
IN_INC_ENCODER_CSI
Input for the evaluation of an
incremental encoder, channel A;
CSI
IN_INC_ENCODER_CSO
Input for the evaluation of an
incremental encoder, channel A;
CSO
MONITOR
Only output data will be
updated.
Values, configurations ans
process data are not written.
For applications that are not
owners of the resource.
10.4.9
MODE_PERIOD (ENUM)
23272
Name
Description
Possible values
MODE_PERIOD
Operating mode of the period
input
UNCHANGED
Setting remains unchanged
IN_FREQUENCY_CSI
Input for frequency measurement;
CSI
IN_FREQUENCY_CSO
Input for frequency measurement;
CSO
IN_PERIOD_RATIO_CSI
Input for absolute and ratiometric
period measurement; CSI
IN_PERIOD_RATIO_CSO
Input for absolute and ratiometric
period measurement; CSO
IN_PHASE_CSI
Input pair for phase measurement,
CSI
IN_PHASE_CSO
Input pair for phase measurement,
CSO
MONITOR
Only output data will be
updated.
Values, configurations ans
process data are not written.
For applications that are not
owners of the resource.