5 Electrical connection
5.1 Wiring
Wiring
Only connect the connector pins as shown in the pin layout�
Unspecified connector pins remain unconnected�
►
Connect all indicated supply cables and GND terminals�
5.2 Ground connection
1: Drill hole for ground connection
To ensure the protection of the device against electrical interference and the
safe function of the device, the housing must be connected to the ground of
the vehicle�
►
Establish a connection between the device and the ground of the vehicle using
M5 screws�
Screws to be used
5.3 Fuses
►
The individual electric circuits must be protected in order to protect the whole
system�
Potential
Description
Pin no.
Fuse
VBB
S
Supply voltage sensors/module
10
≤ 2 A time-lag
VBB
O
Supply voltage outputs
19
≤ 15 A
VBB
R
Supply voltage via relay
01