SafetyController CR7032
20
7.2 Test standards and regulations
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
We reserve the right to make technical alterations without prior notice!
21�08�2017
CR7032 / page 3
CR7032
Technical data
Control systems
Safety-related characteristics
According to IEC 62061:2005
Safety Integrity Level Claim Limit
SIL CL 2
Probability of Dangerous Failure per Hour
PFH
D
1�227 x 10
-7
According to ISO 13849-1:2008
Performance Level
PL
d
Test standards and regulations
Electrical tests
EN 61000-6-2: 2005
Electromagnetic compatibility (EMC)
Immunity
EN 61000-6-4: 2007
+A1: 2011
Electromagnetic compatibility (EMC)
Emission standard
EN 61010: 2010
Safety requirements for electrical equipment for
measurement, control and laboratory use
UN/ECE-R10
Emission standard
Immunity with 100 V/m
ISO 7637-2: 2004
Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: IV; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: IV; function state A
Pulse 5, severity level: III; function state C
(data valid for the 24V system)
Pulse 4, severity level: III; function state C
(data valid for the 12 V system)
Climatic tests
EN 60068-2-30: 2006
Damp heat, cyclic
upper temperature 55°C, number of cycles: 6
EN 60068-2-78: 2002
Damp heat, steady state
Test temperature 40°C / 93% RH,
Test duration: 21 days
EN 60068-2-52: 1996
Salt spray test
Severity level 3 (vehicle)
Mechanical tests
ISO 16750-3: 2012
Test VII; Vibration, random
mounting location: vehicle body
EN 60068-2-6: 2008
Vibration, sinusoidal
10���500 Hz; 0�72 mm/10 g; 10 cycles/axis
ISO 16750-3: 2012
Bumps
30 g/6 ms; 24,000 shocks