149
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
J1939_TX
7688
Unit type = function block (FB)
Unit is contained in the library
ifm_J1939_NT_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
7689
J1939_TX is the easiest method for transmitting single frame messages.
>
Parameters of the inputs
7690
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
execute this function element
FALSE:
unit is not executed
> Function block inputs are not active
> Function block outputs are not specified
CHANNEL
BYTE
CAN interface (1...n) depending on the device
DA
BYTE := 249
DA = Destination Address of the ECU
PGN > 61139: parameter DA is ignored
PGN
DWORD
PGN = Parameter Group Number
permissible = 0...262 143 = 0x00000000...0x0003FFFF
DATA
ARRAY [0..7] OF BYTE
data to be sent (1...8 bytes)
>
Parameters of the outputs
7693
Parameter
Data type
Description
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
function block execution completed without error
242
F2
Error: setting is not possible
250
FA
Error: FiFo is full
– data was lost