2 Safety instructions

General

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 → Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Radio equipment

In general, radio equipment must not be used in the vicinity of petrol stations, fuel depots, chemical
plants or blasting operations.

u

Do not transport and store any flammable gases, liquids or explosive substances near the unit.

Interference of electronic and medical devices

Operation can affect the function of electronic devices that are not correctly shielded.

u

Disconnect the device in the vicinity of medical equipment.

u

Contact the manufacturer of the corresponding device in case of any interference.

Summary of Contents for ANT434

Page 1: ...Operating instructions RF identification system ANT434 ANT435 Read write head 11424518 00 07 2022 GB...

Page 2: ...7 5 1 ID tags 7 5 2 Device overview 7 6 Installation 8 6 1 Notes on the unit installation 8 6 2 Avoiding interference 8 6 3 Mechanical design 8 6 4 Install device 9 6 5 Mounting distances 9 6 6 Posit...

Page 3: ...ss reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright in...

Page 4: ...nded purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty f...

Page 5: ...use The read write head reads and writes ID tags without contact For use the read write head must be connected to the DTE10x evaluation unit The data is converted into digitally coded values and provi...

Page 6: ...plied Read write head 2x hexagonal nut The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using component...

Page 7: ...generates a magnetic field which partly penetrates the antenna coil of the ID tag A voltage is generated by induction that supplies the data carrier with energy The device supports ID tags according t...

Page 8: ...device generates a modulated electrical field with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w...

Page 9: ...device u Fix the device using the supplied nuts M30 ANT434 Fig 3 Flush mounting ANT435 Fig 4 Non flush mounting 6 5 Mounting distances ANT434 Operating mode Distance side A Distance front B For readi...

Page 10: ...u Align the axes of the RFID device and the ID tag in the same way For installation in or on metal use the ID tags provided for this purpose Position the ID tag in the area of the sensing face When do...

Page 11: ...35 D Fig 6 Position the ID tag u Align the ID tag on the central axis of the antenna of the unit ID tag Type Distance read write head D in metal Distance read write head D in plastic E80370 35 mm 35 m...

Page 12: ...ower before connecting the device 7 1 Wiring u Connect the unit to a DTE10x evaluation unit via the M12 connector w Voltage is supplied via the evaluation unit Pin assignment Wiring 4 1 3 L 1 3 4 L DA...

Page 13: ...ltage OK off operating voltage missing flashing slowly deactivated yellow on permanently ID tag detected on pulse ID tag read written successfully flashing quickly error when reading writing on ID tag...

Page 14: ...ANT435 14 9 Operation The read write head is configured via the connected evaluation unit DTE10x Further information on operation can be found in the operating instructions of the evaluation unit www...

Page 15: ...n case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device us...

Page 16: ...or approvals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant f...

Page 17: ...used to identify objects A read write device is used to read the ID tag via a high frequency radio signal An ID tag consists of an antenna an analogue circuit for receiving and transmitting transceive...

Reviews: