Page 1: ...Original operating instructions Compact AS i E STOP safety module AC010S 80269280 00 08 2017 UK...

Page 2: ...ed 4 4 Functions and features 4 5 Function and electrical connection 5 6 Installation 6 6 1 Operating and display elements 6 7 Electrical connection 7 8 Addressing 8 9 Operation 8 9 1 Response times 8...

Page 3: ...tions Follow the operating instructions In case of non observance of notes or standards especially when tampering with and or modifying the unit any liability and warranty is excluded The unit must be...

Page 4: ...with guards Adhere to the specified operating conditions chapter 11 Technical data Use of the unit in the vicinity of chemical and biological media is not permitted In case of faults within the unit...

Page 5: ...configuration software manual The products described herein are designed to be components of a safety oriented machine or control system A complete safety related system normally includes sensors eval...

Page 6: ...mpact AS i E STOP safety module onto a mounting device The upper part of the housing must be fixed to the lower part using all four screws 6 1 Operating and display elements 1 2 3 4 6 5 1 M12 connecto...

Page 7: ...r 2 3 4 1 AS i 2 5 4 3 AS i M12 connector Pin AS i 1 AS i 3 1 Do not change the electrical connections 2 M12 connector 3 LED red LED green LED yellow cannot be seen when the unit is closed 4 LED red a...

Page 8: ...tion Check whether the unit operates correctly Indication by LEDs on the PCB LED green supply voltage OK LED red is lit AS i communication error slave does not participate in the normal exchange of da...

Page 9: ...se time of max 50 ms before application of the signal to AC010S until the safe outputs of the safety monitors switch Here the switching times of the external relays and contactors connected to the rel...

Page 10: ...ity of Dangerous Failure per Hour T Life time Max service life 11 Technical data Electrical design 2 safe inputs 1 non safe LED output Operating voltage 26 5 31 6 V DC Current consumption 50 mA Inputs...

Page 11: ...Maximum number of compact AS i E STOP safety modules 31 EMC EN 61000 6 4 EN 62026 2 Housing materials PC GF20 polycarbonate Housing dimensions 80 x 72 x 105 mm HxWxD Connection M12x1 connector 12 Sca...

Page 12: ...pair and disposal If used correctly no maintenance and repair measures are necessary Only the manufacturer is allowed to repair the unit After use dispose of the unit in an environmentally friendly wa...

Page 13: ...13 UK...