Technical data
25
ENGLISH
Operating voltage [V] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ... 36 DC
1)
Current consumption [mA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 50
Current rating [mA] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Reverse polarity and overload protected
up to 40 V
Short-circuit protected; Watchdog
Voltage drop [V]. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 2
Power-on delay time [s] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3
Switching frequency [Hz] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 ... 1
Analogue output. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ... 20 mA / 0 ... 10 V
Max. load current output [
Ω
] . . . . . . . . . . . (U
B
- 10) x 50; 700 at U
B
= 24V
Min. load with voltage output [
Ω
] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000
Response time analogue output [ms]. . . . . . . . . . . . . . . . . . . . . . . . . . . < 3
Accuracy / deviations (in% of the span)
- Accuracy of switch point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ± 0.5
- Characteristics deviation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ± 0.5
- Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ± 0.25
- Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < ± 0.1
- Long-time stability (in% of value of measuring range / 6 months). < ± 0.05
- Temperature coefficients (TEMPCO) in the compensated
temperature range 0 ... +80°C (in% of the span/10K)
greatest TEMPCO of the zero point / of the span . . . . . . . . . . . . . 0.2 / 0.2
Materials (wetted parts) . . . . . . . . . . . . . . . . . . . . . stainless steel (316S12);
ceramics; FPM (Viton)
Housing material . . . . . . . . stainless steel (304S15); stainless steel (316S12);
PC (Macrolon); Pocan; PEI; FPM (Viton); in addition PTFE (PY9954)
Protection / Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 67 (IEC 60529)
Protection class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . III (EN 50178)
Insulation resistance [M
Ω
] . . . . . . . . . . . . . . . . . . . . . . . . > 100 (500 V DC)
Shock resistance [g] . . . . . . . . . . . . . . . . . . . . 50 (DIN / IEC 68-2-27, 11ms)
Vibration resistance [g] . . . . . . . . . . . . . 20 (DIN / IEC 68-2-6, 10 - 2000 Hz)
Switching cycles min. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 million
Operating temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20 ... +80
Medium temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25 ... +80
Storage temperature [°C] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40 ... +100
EMC
EN 61000-4-2 ESD: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 / 8 KV
EN 61000-4-3 HF radiated: . . . . . . . . . . . . . . . . . . . . . . . . . 10 V/m
EN 61000-4-4 Burst: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 KV
EN 61000-4-5 Surge: . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 / 1 KV
EN 61000-4-6 HF conducted: . . . . . . . . . . . . . . . . . . . . . . . . 10 V
1)
to EN50178, SELV, PELV