23
UK
10.3.3 Table repeatability and accuracy
Values for sampling rate 15 Hz
Distance
in [mm]
Repeatability
Accuracy
white
90 % remission
grey
18 % remission
white
90 % remission
grey
18 % remission
300���1000
± 11,0 mm
± 13,0 mm
± 31,0 mm
± 33,0 mm
1000���2000
± 28,0 mm
± 30,0 mm
± 48,0 mm
± 50,0 mm
2000���3000
± 50,0 mm
± 50,0 mm
± 70,0 mm
± 70,0 mm
3000���4000
± 85,0 mm
± 85,0 mm
± 105,0 mm
± 105,0 mm
4000���5000
± 105,0 mm
—
± 125,0 mm
—
5000���6000
± 145,0 mm
—
± 165,0 mm
Values for sampling rate 1 Hz
Distance
in [mm]
Repeatability
Accuracy
white
90 % remission
grey
18 % remission
white
90 % remission
grey
18 % remission
300���1000
± 8,0 mm
± 10,0 mm
± 28,0 mm
± 30,0 mm
1000���2000
± 25,0 mm
± 25,0 mm
± 45,0 mm
± 45,0 mm
2000���3000
± 38,0 mm
± 38,0 mm
± 58,0 mm
± 58,0 mm
3000���4000
± 70,0 mm
± 70,0 mm
± 90,0 mm
± 90,0 mm
4000���5000
± 100,0 mm
—
± 120,0 mm
—
5000���6000
± 100,0 mm
—
± 120,0 mm
*Range referred to black (6 % remission) ≤ 4000 mm.
The values apply at:
• constant ambient conditions (23°C / 960 hPa)
• only after unit powered up for 10 minutes
• Extraneous light on the object max�: 100 klx