background image

3

UK

2

OUT on

OUT off

Remove the object, then press the [OUT off] button 

 

LED goes out

 

>

The sensor is to switch when no object is detected:

Press the [OUT on] button when no object is present.

1. 

Position the object and press the [OUT off] button.

2. 

Setting of the maximum sensitivity

The sensor is to switch when the object is detected:

Align the unit so that no light is reflected.

 

First press the [OUT on] button then the [OUT off] button.

 

The sensor is to switch when no object is detected:

Align the unit so that no light is reflected.

 

First press the [OUT off] button then the [OUT on] button.

 

Lock or unlock the push buttons:

Press both buttons for 10 s.

 

Acknowledgement is indicated by a change of the yellow LED status.

 

>

Programming failed:

The yellow LED flashes quickly (8 Hz).

 

>

Measured value difference too small.

• 

Max. programming time of 15 min. exceeded.

• 

Operation

The LED is lit when the output is switched. 

• 

Maintenance

Keep the lens of the sensor free from soiling. For cleaning do not use any solvents 
or cleaning agents which could damage the plastic lenses.

Reviews: