Operating instructions
Retro-reflective sensor
OGP50x
UK
704072/ 01
02 / 2008
Page 1: ...Operating instructions Retro reflective sensor OGP50x UK UK 704072 01 02 2008 ...
Page 2: ...n prismatic reflector Ø 80 mm E20005 2 Installation Fit the prismatic reflector or the reflective tape behind the object to be detected Align the retro reflective sensor to it and and secure it to a bracket Maximum range only with accurate alignment 3 Electrical connection Disconnect power Connect the unit as follows Cable Connector Pin connection L BN pin 1 L BU pin 3 load BK pin 4 pin 2 Core col...
Page 3: ...o the object The LED flashes 2 Remove the object Press OUT off The sensitivity is set without object The LED goes out The programming is finished 4 2 The sensor is not to switch when the object is detected Position the object see figure 1 and press OUT off for 2 s Remove the object see figure 2 and press OUT on The settings can also be carried out first without object step 1 and then with object s...
Page 4: ...ff then OUT on 4 5 Locking or unlocking the buttons The unit can be locked electronically to prevent unintentional settings Press OUT on and OUT off simultaneously for 10 s Acknowledgement is indicated by a change of the LED status 5 Operation Check whether the unit operates correctly The LED lights when the switching output is switched 6 Maintenance Keep the lens of the sensor free from soiling F...