12
9 Parameter setting
During the parameter setting process the unit remains in the operating mode� It
continues its monitoring function with the existing parameters until parameter set-
ting has been terminated�
9.1 Parameter setting general
Each parameter setting requires 3 steps:
1
Parameter selection
►
Press [Mode/Enter] until the
requested parameter is displayed�
2
Setting of the parameter value
►
Press [Set] and keep it pressed�
> Current setting value of the param-
eter flashes for 5 s�
> After 5 s: The setting value is
changed: incremental by press-
ing briefly or scrolling by holding
pressed�
The numerical values are incremented continuously� If the value is to be reduced: Let
the display move to the maximum setting value� Then the cycle starts again at the
minimum setting value�
3
Acknowledgement of the parameter
value
►
Press [Mode/Enter] briefly�
> The parameter is displayed again�
The new setting value is stored�
Setting of other parameters:
►
Start again with step 1�
Finishing the parameter setting:
►
Press [Mode/Enter] several times until the current measured value is displayed or wait
for 15 s�
> The unit returns to the operating mode�
• If [SLoc] is displayed when attempting a modification of a parameter value, the
sensor is locked via software� This locking can only be removed via a param-
eter setting software�
• In case of parameter setting with the user interface of the ifm Container pro-
gram, the values can be directly entered in the specified fields�