9.6.2  Reset all parameters to the factory setting

 

Select [rES], then press [Set] and keep it pressed until 

[----] is dis-

played�

 

Press [Mode/Enter] briefly�

The factory setting is listed at the end of the instructions (→ 13 Factory 

setting)�

It makes sense to write your own settings in this table before executing the 

function�

9.7  Setting of the preset meter / pulse value (ImPS)

6 setting ranges are available:

LED

Display

in steps of

Value

1

3

0 0� 0 2

��� 9 9� 9 8

0�02 gal

0�02���99�98 gal

2

3

1 0 0� 0

��� 9 9 9� 9

0�1 gal

100�0���999�9 gal

3

3

1 0 0 0

��� 9 9 9 9

1 gal

1 000���9 999 gal

4

3 + 5

1 0� 0 0

��� 9 9� 9 9

10 gal

10 000���99 990 gal

5

3 + 5

1 0 0� 0

��� 9 9 9� 9

100 gal

100 000���999 900 gal

6

3 + 5

1 0 0 0

��� 9 0 0 0

1000 gal

1 000 000���9 000 000 gal

Setting operation

:

 

► Set [OU1] to [ImP] (→ 9.3.2).

 

Press [Mode/Enter] until [ImPS] is displayed�

 

Press [Set] and keep it pressed�

 

> The current numerical value flashes for 5 s, then one of the 4 digits becomes 

active (digit flashes, can be changed)�

 

Set the requested value as indicated in the following table�

 

First select the requested setting range� Then set the figure from the left digit to the 

right digit�

 

Press [Mode/Enter] briefly when all 4 digits are set�

As soon as the first digit flashes there are 3 options:

Summary of Contents for efector 300 SU8001

Page 1: ...Operating instructions Ultrasonic flow rate sensor SU8001 704851 00 07 2010 US...

Page 2: ...Start up delay dSt 9 4 8 Customer specific calibration CGA 10 5 Installation 11 5 1 Installation location 11 5 2 Installation in pipes 13 5 3 Protection against high medium temperatures 14 6 Electrica...

Page 3: ...the output logic 22 9 5 4 Customer specific calibration of the curve of measured values 22 9 5 5 Calibration reset 23 9 5 6 Setting the start up delay 23 9 5 7 Setting the damping of the measured val...

Page 4: ...un wanted effects in your application That is why installation electrical connection set up operation and mainte nance of the unit must be carried out by qualified personnel authorised by the plant o...

Page 5: ...totalising meter 9 3 1 or switching signal for preset counter 9 3 2 OUT2 4 selection options switching signal for volumetric flow limit value 9 2 2 or switching signal for temperature limit value 9 4...

Page 6: ...tity monitoring with pulse output Output 1 provides a counting pulse if the value set in ImPS is reached 9 3 1 4 3 2 Consumed quantity monitoring with preset meter 2 types of monitoring are possible T...

Page 7: ...t by means of the distance between SPx and rPx SPx maximum value rPx minimum value 1 2 HY hysteresis FE window examples for volumetric flow monitoring When set to the window function the set and reset...

Page 8: ...etween 0 and 10 V It is also indicated Volumetric flow above the measuring range output signal 10 V Current output 4 20 mA example volumetric flow monitoring Factory setting Measuring range scaled MEW...

Page 9: ...are 3 options The volumetric flow quantity increases quickly and reaches the switch point good range within dSt outputs remain active The volumetric flow quantity increases slowly and does not reach t...

Page 10: ...ctive 7 dSt elapsed Q has not reached good range output is reset 8 Q reaches good range output becomes active 4 8 Customer specific calibration CGA This calibration changes the slope of the curve of m...

Page 11: ...the unit so that the measuring pipe is always completely filled Arrange for inlet and outlet pipe lengths Disturbances caused by bends valves reductions etc are compensated for It applies in particula...

Page 12: ...tion locations Directly in front of a falling pipe In a falling pipe FF flow direction At the highest point of the pipe system Directly in front of the spout of a pipe F flow direction On the suction...

Page 13: ...r B into the pipe A 2 Place the seals C and install the unit according to the marked flow direction 3 Screw the adapter B with the threads D until it is hand tight 4 Tighten the two adapters in opposi...

Page 14: ...equipment must be adhered to Voltage supply to EN50178 SELV PELV Disconnect power Connect the unit as follows Pin1 Ub Pin3 Ub Pin4 OUT1 Switching signal limit values for volumetric flow Switching sig...

Page 15: ...LED 7 LED 8 switching state of the corresponding output 9 Alphanumeric display 4 digits indication of the current volumetric flow if SELd FLOW is set indication of the meter count if SELd TOTL is set...

Page 16: ...16 8 Menu 8 1 Menu structure Mode Enter Set gal current meter count in gal gal stored meter count in gal...

Page 17: ...ure AEP Analogue end value for volumetric flow or temperature DIn2 Configuration of the input pin 2 for meter reset EF Extended functions opening of menu level 2 HI LO Maximum minimum value memory for...

Page 18: ...am eter flashes for 5 s After 5 s The setting value is changed incremental by press ing briefly or scrolling by holding pressed Numerical values are incremented continuously If the value is to be redu...

Page 19: ...ess Mode Enter Set for 10 s Loc is displayed During operation Loc is briefly displayed if you try to change parameter values Press Mode Enter Set for 10 s uLoc is displayed When delivered unlocked Tim...

Page 20: ...nction normally closed Select SP2 and set the value at which the output switches Select rP2 and set the value at which the output switches back 9 2 3 Scaling of the analogue value for volumetric flow...

Page 21: ...vals from 1 hour to 8 weeks Press Mode Enter briefly 9 3 4 Switch off the meter reset Select rTO and set OFF The meter is only reset after overflow factory setting 9 3 5 Settings for meter reset by an...

Page 22: ...ement providing the highest accuracy 9 5 2 Configuration of the standard display Select SELd and determine the standard process category FLOW display shows the current volumetric flow value in the sta...

Page 23: ...d determine the value On output 2 switches ON in case of an error the analogue signal goes to the upper end stop value OFF output 2 switches OFF in case of an error the analogue signal goes to the low...

Page 24: ...0 999 9 gal 3 3 1 0 0 0 9 9 9 9 1 gal 1 000 9 999 gal 4 3 5 1 0 0 0 9 9 9 9 10 gal 10 000 99 990 gal 5 3 5 1 0 0 0 9 9 9 9 100 gal 100 000 999 900 gal 6 3 5 1 0 0 0 9 0 0 0 1000 gal 1 000 000 9 000 0...

Page 25: ...t kept pressed 1 0 1 2 Wait 3 s do not press any button The digit following on the right flashes becomes active 8 1 2 3 no pushbutton pressed after 3 s 8 1 2 3 after 3 s 8 1 2 3 after 3 s 8 1 2 3 If t...

Page 26: ...nc If output 2 is configured as analogue output the output signal is at the final value of the measuring range during the power on delay time 10 1 Read the set parameters Press Mode Enter briefly to s...

Page 27: ...Set briefly The latest measured values are displayed IOE Flow sensor faulty Loc Setting pushbuttons locked parameter change rejected VMR final value of the measuring range 10 4 General operating cond...

Page 28: ...28 11 Scale drawing 1 Display 2 Connector electrical connection 3 Marking direction of flow...

Page 29: ...n load for voltage output k 2 Pulse value 0 02 9000 10 Pulse length s min 0 3 max 2 Power on delay time s 10 Flow monitoring gpm gph Measuring range 0 00 26 44 0 1585 Resolution 0 02 1 Display range 0...

Page 30: ...tance M 100 500 V DC Shock resistance g 20 DIN IEC 68 2 27 11ms Vibration resistance g 5 DIN IEC 68 2 6 55 2000 Hz EMC IEC 1000 4 2 ESD 4 8 KV IEC 1000 4 3 HF radiated 10 V m IEC 1000 4 4 Burst 2 KV I...

Page 31: ...mPR YES OU1 Hno OU2 I SP2 FLOW 20 02 rP2 FLOW 16 02 SP2 TEMP 136 5 rP2 TEMP 112 0 ASP FLOW 0 00 AEP FLOW 24 02 ASP TEMP 14 0 AEP TEMP 161 0 DIn2 EDG CGA 100 FOU1 OFF FOU2 OFF dSt 0 0 P n PnP dAP 0 6 r...

Reviews: