4
1 Preliminary note
1.1 Symbols used
►
Instruction
>
Reaction, result
[…] Designation of pushbuttons, buttons or indications
→
Cross-reference
Important note
Non-compliance can result in malfunction or interference�
Information
Supplementary note�
2 Safety instructions
•
Please read this document prior to set-up of the unit� Ensure that the product is
suitable for your application without any restrictions�
•
Work on compressed air systems as well as mounting, setting for operation
and set-up of the unit must be carried out by qualified personnel� When doing
so, state of the art as well as safety and accident prevention regulations have
to be adhered to�
•
Ensure before mounting the components into or removing them from the
compressed air system that the installation is at a standstill and no pressure is
applied�
•
Improper or non-intended use may lead to malfunctions of the unit or to un-
wanted effects in your application� That is why installation, electrical connec-
tion, set-up, operation and maintenance of the unit must only be carried out by
qualified personnel authorised by the machine operator�
• Check the compatibility of the product materials (→ 12 Technical data) with the
media to be measured in all applications�
3 Functions and features
The unit monitors the standard volume flow of compressed air in industrial use�
It detects the 4 process categories flow velocity, volumetric flow quantity, con-
sumed quantity, medium temperature�
•
Applications: compressed air systems in industrial use�