Timing diagram inputs/outputs
The evaluation time
t
E
differs depending on the selected image section
and the number of contours.
Typical evaluation times:
80...150 ms (without connection to the operating program)
1...2 s (with connection to the operating program)
The trigger disable time
t
p
is max. 1 s if no connection between ope-
rating program and sensor has been established. It is max. 3 s if the
operating program is connected with the sensor.
10
IO
NIO
t
A
t
A
triggering on
positive edge
OUT
ready
OUT
not ready
trigger
input
output
READY
output
OUT
t
P
t
P
trigger
enabled
trigger
disabled
trigger
enabled
trigger
disabled
trigger
enabled
switching
input
IN0
switching
input
IN1
output
READY
trigger
input
change of the
configuration file
t
E
t
E
OK
not OK