background image

3

UK

1 Preliminary note

1.1 Symbols used

Instruction

>

Reaction, result

Cross-reference
Important note 

Non-compliance can result in malfunctions or interference
Information 

Supplementary note

2 Safety instructions

According to the cULus approval

Caution - Use of controls or adjustments or procedures other than those specified 

herein may result in hazardous radiation exposure

Visible laser light; CLASS 1 LASER PRODUCT 

IEC 60825-1 : 2007  

Complies with 21 CFR 104010 except for deviations pursuant to Laser 

Notice No 50, dated June 2007 

Position of the product label

Additional label

Beispiel OJ5116

Summary of Contents for efector 200 OJ51 Series

Page 1: ...Operating instructions Through beam sensor OJ51xx laser 704810 00 05 2010 UK...

Page 2: ...on 4 5 Electrical connection 5 6 Setup 5 7 Settings 6 7 1 Setting of the sensitivity with stationary objects 6 7 2 Setting of the sensitivity with moving objects 7 7 3 Setting of the maximum sensitivi...

Page 3: ...y instructions According to the cULus approval Caution Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure Visible laser light CLA...

Page 4: ...units with side lens are identical Secure the receiver OJELxx to a bracket Align the transmitter OJSLxx to the receiver and secure it in the same way Maximum range is only possible with precise alignm...

Page 5: ...P L L 3 2 4 1 teach Transmitter DC 1 3 L L Programming of the output function by pushbutton or programming wire 7 5 Programming the output function 6 Setup The through beam sensor is supplied ready to...

Page 6: ...bject Press once The yellow and green LEDs go out for approx 1 s After approx 3 s the green LED is on The unit is in the operating mode Setting steps 2 and 3 can also be carried out in reverse order T...

Page 7: ...ramming mode of the unit Press for about 2 s until the red LED flashes The red LED goes out the yellow and green LEDs flash alternately The unit is in the programming mode 2 Allow objects to pass thro...

Page 8: ...rupt the light beam Press the setting button twice steps 2 and 3 The maximum sensitivity can also be set in exactly the same way using the programming wire pin 2 WH To activate the functions the progr...

Page 9: ...rnately 2 Hz output short circuited Flash alternately 1 Hz internal fault output is not switched 9 Maintenance repair and disposal Keep the lenses of the sensor free from soiling For cleaning do not u...

Reviews: