6.3 Setting of the maximum sensitivity*
Go into the programming mode (→ step 1).
►
Align the unit so that no light is reflected
►
Press the setting button twice (→ steps 2 and 3).
►
* The maximum sensitivity can also be set in exactly the same way using the programming
wire (pin 2 / WH). To activate the functions the programming wire is connected for the appro
-
priate time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units.
6.4 Electronic lock
Activate the lock by connecting the programming wire for about 15 s – 20 s*
Deactivate the lock by connecting the programming wire again for 15 s – 20 s*
* To activate the functions the programming wire (pin 2 / WH) is connected to L+ (pin 1 / BN)
for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time.
6.5 Programming the output function*
Press for 10 s
►
The red LED starts to flash fast after 2 s
>
Then the yellow and green LEDs flash
>
alternately
After 10 s all LEDs go off, the output
>
function has changed from light-on mode
to dark-on mode (or vice versa).
* The output function can be programmed in exactly the same way using the programming
wire (pin 2 / WH). To activate the functions the programming wire is connected for the appro
-
priate time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units.