More functions in the ecomatmobile controller
Data access and data check
223
10.4
Data access and data check
The functions described in this chapter control the data access and enable a data check.
10.4.1
Function SET_DEBUG
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController:
CR2500
Function symbol:
SET_DEBUG
ENABLE
DEBUG
Description
SET_DEBUG handles the DEBUG mode without active test input (
→
chapter TEST mode,
→
page
If the input DEBUG of the function is set to TRUE, the programming system or the downloader, for
example, can communicate with the controller and execute system commands (e.g. for service
functions via the GSM modem CANremote).
NOTE
In this operating mode a software download is not possible because the test input is not connected to
supply voltage.
Parameters of the function inputs
Name
Data type Description
ENABLE
BOOL
TRUE: function is executed
FALSE: function is not executed
DEBUG
BOOL
TRUE: debugging via the interfaces possible
FALSE: debugging via the interfaces not possible