Function and features
The preset counter evaluates the input pulses, processes them
according to the programmed functions and displays the result in
two 6-digit and one 4-digit displays and switches the output relays
depending on the programmed output performance.
• Counts pulses from incremental shaft encoders, mechanical or
electronic pulse pick-ups.
• Supply of the pulse pick-ups via integrated power supply.
• Programming possibilities for pulse processing and display.
• Preprogrammed basic setting.
• Preset.
Operation and display elements
Mounting
There are two brackets with threaded holes at the back of the unit.
Mount the counter in your plant using the screws supplied; panel
cut-out: 67mm x 92mm.
8
7
8
P
Reset
4
5
6
C
1
2
3
Out1 Out2
<>
0
9
S
1
2
3
4
5
6
7
8
9
10
1. LEDs; lit when the corresponding
relay is energised
2. front reset
3. sets preset 1 to the actual value
display
4. changing of the display preset 1/
preset 2
5. actual value display
6. preset display
7. display relay 1 / 2 and display of
parameter address
8. change into programming mode;
acknowledgement of parameter
address and parameter value
9. deletes the display
10. numeral keys