C
ABINET
C
ONTROLLER
CR0302
PAGE
16
CR0302
Characteristics of the outputs
Digital outputs
■
Semi conductor outputs, positive switching (high side), with diagnostic capability
X3:01...04, OUT 00...OUT 03
short-circuit and overload protected
can be configured as ...
switching voltage
10...32 V DC
switching current
max. 2 A
■
PWM outputs
PWM frequency
max. 250 Hz
setting resolution
0,1 %
load current
max. 2 A
The outputs 0...3 are combined and have a common U
COM
connection.
Digital outputs
■
Semi conductor outputs, positive switching (high side),
X3:06...09, OUT 04...OUT 07
short-circuit and overload protected
switching voltage
10...32 V DC
switching current
max. 2 A
The outputs 4...7 are combined and have a common U
COM
connection.
Digital outputs
■
Semi conductor outputs, positive switching (high side),
X5:01...18, OUT 08...OUT 11
short-circuit and overload protected
Schaltspannung
10...32 V DC
Schaltstrom
max. 2 A
The outputs 8...11 are combined and have a common U
COM
connection.
External free-wheeling diode
To protect the outputs free-wheeling diodes must be connected in parallel with the
load in the case of high switch-off energies (inductive or capacitive loads).
also see wiring, page 5