IFM Electronic CR0505 Mounting And Installation Instructions Manual Download Page 8

C

LASSIC

C

ONTROLLER

CR0505

PAGE

8

*) only positive sensor signals
with diagnostic capability

226

5,5

26

80

15

45°

153

LED

43

200,5

±1

±0,5

±1

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen

18.09.2015

CR0505

Mobile controller

ClassicController

2nd CAN interface

for gateway function

according to SAE J 1939

Programming

according to IEC 61131-3 

Operating voltage

10...32 V DC

We reserve the right to make technical alterations without prior notice.

CR0505 / page 1

Technical data

Controller as black box system

for the implementation of a central or decentralised system design

Housing

closed, screened metal housing with flange fastening

Dimensions (H x W x D)

153 x 226 x 43 mm

Mounting

screw connection by means of 4 M5xL screws according  to DIN 7500 or DIN 7984

mounting position horizontal or vertical to the mounting wall

Connection

55-pin connector, latched, protected against reverse polarity, type AMP or Framatome

AMP junior timer contacts, crimp connection 0.5/2.5 mm²

Weight

1.2 kg

Housing / storage temperature

– 40...85 °C (depending on the load) / – 40...85 °C

Protection

IP 67 (for inserted plug with individually sealed cores e.g. EC2084)

Input/output channels

max. 24 (the total number which is available depends

total

on the wiring and configuration of the controller)

Inputs

max. 24 (corr. to 0 outputs)

possible configurations

Outputs

max. 8 (corr. to 16 inputs)

possible configurations

Number

Signal

Version

8

digital

for positive sensor signals, with diagnostic capability

B

L

or

analogue

0...10/32 V DC, 0/4...20 mA or ratiometric

A

8

digital

for positive sensor signals

B

L

4

digital

for positive sensor signals, with diagnostic capability

B

L

or

frequency

max. 50 kHz

I

L

4

digital

for positive/negative sensor signals, with diagnostic capability

*

B

L/H

or

frequency

max. 1 kHz

I

L

Number Signal

Version

8

digital

positive switching (High Side), with diagnostic capability

B

H

or

PWM

PWM frequency 20...250 Hz

PWM

or

current-controlled

0,1...4 A 

PWM

I

Abbreviations

A

= analogue

B

H

= binary High Side

B

L

= binary Low Side

FRQ/CYL = frequency inputs
I

H

= pulse High Side

I

L

= pulse Low Side

PWM

= pulse width modulation

PWM

I

= current-controlled output

%IWx

= IEC address for analogue input

%IX0.xx = IEC address for binary input
%QX0.xx = IEC address for binary output

Summary of Contents for CR0505

Page 1: ...Mounting and installation instructions ClassicController R 360 CR0505 ENGLISH R 7390428 02 09 2015 ...

Page 2: ...rs The wiring of all signals in connection with the SELV circuit of the unit must also comply with the SELV criteria safe extra low voltage safe electrical separation from other electric circuits If the supplied SELV voltage has an external connection to ground SELV becomes PELV the responsibility lies with the user and the respective national regulations for installation must be complied with All...

Page 3: ...stem offer high protection of the machine The controllers can be used as CANopen master The controllers ClassicController R 360 are not approved for safety relevant tasks in the field of safety of persons 2 Programming The application software can be easily created by the user with the ifm programming system CODESYS according to IEC 61131 3 In addition to the programming system the complete system...

Page 4: ...sition Align the controller in such a way that the cable entry of the connector faces downwards CLASSICCONTROLLER CR0505 PAGE 4 Screws to be used examples Standard Button head hexagon socket screws M5 x L ISO 7380 Cylinder screws with hexagon socket and low head M5 x L DIN 7984 Cutting screws for metric ISO thread with low head DIN 7500 Screw material steel or stainless steel Example button head h...

Page 5: ...se compensating elements if there is no flat mounting surface available 3 4 Heat dissipation Ensure sufficient heat dissipation as the internal heating of the electronics is conducted away via the housing In case of sandwich mounting of controllers use spacers ENGLISH CLASSICCONTROLLER CR0505 PAGE 5 ...

Page 6: ...e inputs and outputs within one group of connections In the applications the following must be observed as regards the use of the ter minals as input and output Within one output group inputs and outputs should not be mixed One output group is marked by a common VBBX potential The background is a possible internal cross connection of the outputs from the externally supplied inputs This may occur u...

Page 7: ... must be maintained by the user the housing must not be opened The repair of the controller may only be carried out by the manufacturer The disposal must be carried out accord ing to the corresponding national environmental regulations 6 Approvals standards The EC declaration of conformity and approvals can be found at www ifm com Data sheet search CR0505 More information ENGLISH CLASSICCONTROLLER...

Page 8: ...ature 40 85 C depending on the load 40 85 C Protection IP 67 for inserted plug with individually sealed cores e g EC2084 Input output channels max 24 the total number which is available depends total on the wiring and configuration of the controller Inputs max 24 corr to 0 outputs possible configurations Outputs max 8 corr to 16 inputs possible configurations Number Signal Version 8 digital for po...

Page 9: ...stem excess temperature monitoring Process monitoring concept Two relays according to EN 954 monitor two groups of 4 outputs each Physical memory Flash 2 MByte RAM 256 kByte Remanent memory 32 kByte Memory allocation See system manual www ifm com Data sheet search CR0505 More information Status indication three colour LED R G B Operating states Status LED Test standards and regulations Climatic te...

Page 10: ... positive sensor signals with diagnostic capability evaluation with integrated comparator switch on level 0 43 0 73 UB switch off level 0 29 UB input resistance 2 86 kΩ input frequency max 50 kHz Digital inputs BL H IL Digital inputs for positive negative sensor signals positive with diagnostic capability IX1 04 07 switch on level 0 7 UB can be configured as switch off level 0 4 UB input resistanc...

Page 11: ...rmally open contacts in series to 2 groups of 4 semiconductor outputs for electrically isolated Sustained forcing by means of hardware and additional controlling deactivation of the outputs by means of user program The relays must always be switched without load total current max 12 A per group switching current 0 1 15 A overload current 20 A number of operating cycles 10 6 without load switching ...

Page 12: ...erung programming Pin 03 PC D Sub 9 pin 07 TxD RS 232 Interface Programmierung programming Pin 02 PC D Sub 9 pin 13 ERROR Fehlerausgang BH error output BH 24 TEST TEST Eingang test input EIN AUSGÄNGE inputs outputs entrées sorties Pin EINGÄNGE Konfiguration AUSGÄNGE Konfiguration diagnosefähig relaisgeschaltet pin INPUTS configuration OUTPUTS configuration diagnostic capability relay switched INPU...

Reviews: