The plug must be accessible after
the air conditioner has been installed
so that it may be pulled out if necessary.
The connection must have
sufficient earthing.
If the power cord is damaged, it must
be replaced by authorized service
personnel only.
Note
The cable wires have been connected to the
main PCB of the indoor unit by the manufacturer
according to the model without terminal block.
Refrigerant piping connection
The piping can move in 3 directions
as indicated by numbers in the figure.
When the piping is moving in direction
1 or 3, cut a notch along the groove on
the side of the indoor unit with a cutter.
Move the piping in the direction of the
wall hole and bind the copper pipes, the
drain pipe and the power cables, together
with tape with the drain pipe at the
bottom, so that water can flow freely.
Shape the connection pipe
Do not remove the cap from the pipe
until connecting it, to prevent dampness
or dirt from entering it.
If the pipe is bent or pulled too often,
it will become stiff. Do not bend the pipe
more than three times at one point.
When extending the rolled pipe,
straighten the pipe by unwinding
it gently as shown in the figure.
Connecting the pipes
Remove the indoor unit pipe cap.
Check that there is no debris inside.
Insert the flare nut and create
a flange at the extreme end
of the connection pipe.
Tighten the connections by using two
wrenches working in opposite directions.
Connections to the indoor unit
Indoor unit condensed
water drainage
Place the drain hose below the piping,
taking care not to create siphons.
The drain hose must slant downwards
to aid drainage.
31
Summary of Contents for FASTCOOL CI12
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ...For Internal use only IU221OTUSM012 REV D...
Page 5: ...01...
Page 6: ...02...
Page 14: ...10...
Page 16: ......
Page 18: ...Remote Control 1 14...
Page 19: ...Meanings of Symbols 1 15...
Page 20: ...16...
Page 21: ......
Page 23: ...19...
Page 45: ...41 Applicable in selected models only...
Page 46: ...42...