background image

The plug must be accessible after 
the air conditioner has been installed 
so that it may be pulled out if necessary.
The connection must have 
sufficient earthing.
If the power cord is damaged, it must 
be replaced by authorized service 
personnel only. 

Note 

The cable wires have been connected to the 

main PCB of the indoor unit by the manufacturer 
according to the model without terminal block. 

Refrigerant piping connection

The piping can move in 3 directions 
as indicated by numbers in the figure.
When the piping is moving in direction 
1 or 3, cut a notch along the groove on 
the side of the indoor unit with a cutter. 
Move the piping in the direction of the 
wall hole and bind the copper pipes, the 
drain pipe and the power cables, together 
with tape with the drain pipe at the 
bottom, so that water can flow freely. 

Shape the connection pipe 
Do not remove the cap from the pipe 
until connecting it, to prevent dampness 
or dirt from entering it. 
If the pipe is bent or pulled too often, 
it will become stiff. Do not bend the pipe 
more than three times at one point. 
When extending the rolled pipe, 
straighten the pipe by unwinding 
it gently as shown in the figure. 

Connecting the pipes

Remove the indoor unit pipe cap. 
Check that there is no debris inside.
Insert the flare nut and create 
a flange at the extreme end 
of the connection pipe. 
Tighten the connections by using two 
wrenches working in opposite directions. 

Connections to the indoor unit

Indoor unit condensed 
water drainage

Place the drain hose below the piping, 
taking care not to create siphons. 
The drain hose must slant downwards 
to aid drainage. 

31

Summary of Contents for FASTCOOL CI12

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...For Internal use only IU221OTUSM012 REV D...

Page 5: ...01...

Page 6: ...02...

Page 7: ...ation Troubleshooting 43 Installation report 44 Warranty 48 Precautions This appliance conforms to safety requirements Inappropriate use can lead to injury or damage to property Please read this user...

Page 8: ...operly into the socket thereby avoiding the risk of electric shock or fire due to improper contact Check that the socket is suitable for the plug otherwise have a suitable socket installed Do not inst...

Page 9: ...recycled or disposed of properly Please discard the batteries as sorted municipal waste at the accessible collection point Never remain directly exposed to the flow of cold air for all long time The...

Page 10: ...physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning the use of the appliance in a safe way and understand the ha...

Page 11: ...give eWaste to informal and unorganized sectors such as local scrap dealers and rag pickers Do not dispose off your product in garbage bins along with municipal waste that ultimately reaches landfills...

Page 12: ...FILTER 03 SPECIAL FILTER 04 LED DISPLAY 05 TERMINAL BLOCK COVER 06 HORIZONTAL DEFLECTORS 07 VERTICAL DEFLECTORS 08 EMERGENCY BUTTON 09 INDOOR UNIT RATING LABEL 10 ENERGY LABEL 11 24 DEGREE TEMPERATURE...

Page 13: ...n of indicators may vary according to the model and may not correspond to the appearance of the units that have been purchased but their function remain same 09 1 POWER 2 SLEEP 3 TEMPERATURE DISPLAY T...

Page 14: ...10...

Page 15: ...11 01 AIR OUTLET GRILLE 02 OUTDOOR UNIT RATING LABEL 03 BIG HANDLE COVER 04 GAS VALVE 05 LIQUID VALVE 06 BRAND LOGO...

Page 16: ......

Page 17: ...e clock time Press the power button and the clock time will stop blinking Later If user want to change time user can remove the batteries and repeat the same process Note User can set clock time in 24...

Page 18: ...Remote Control 1 14...

Page 19: ...Meanings of Symbols 1 15...

Page 20: ...16...

Page 21: ......

Page 22: ...ress C4 0 6 0 6 5th Press C5 0 5 1 2 1 0 0 9 0 8 0 7 0 6 1 3 1 2 1 0 0 8 0 6 1 2 1 0 0 8 0 6 1 7 1 8 2 0 1 7 1 8 1 5 1 5 1 2 1 2 1 0 1 0 Model Name 1 7 1 5 1 2 1 0 0 8 CI12 CI13 HI13 CI15 CI18 CI19 HI...

Page 23: ...19...

Page 24: ...e the function ECO One press activates the ECO Mode ANTI MILDEW Hold Eco button for 3 sec to activate the ANTI MILDEW Mode MODE Selects the mode operation SUPER In Cool Mode pressing this button will...

Page 25: ...FYING FAN ONLY OPERATION HEATING SIGNAL RECEPTION TIMER OFF TIMER ON AUTO FAN LOW FAN SPEED MIDDLE FAN SPEED HIGH FAN SPEED SLEEP FLAP SWING SUPER AMBIENT TEMPERATURE ECO ANTI MILDEW C1 C2 C3 C4 C5 Am...

Page 26: ...time in the remote control or if you change them you need to program the remote control of only cooling or heat pump air conditioners This is very easy As soon as you insert the batteries COOL and HEA...

Page 27: ...dehumidifying the air in the room If required it can also heat the air in models with heat pump The air drawn in by the fan enters through the grille of the front panel and passes through the air filt...

Page 28: ...he air conditioner adjust the temperature speed and direction of airflow by pressing the buttons shown in the figure As per national regulation the default 0 temperature of 24 C is set each time once...

Page 29: ...ill the air conditioner switches ON should be displayed Then press the Timer button again To cancel the set Start Time press the Timer button again Note In case of a power outage it is necessary to se...

Page 30: ...will automatically choose the temperature settings and fan speed To activate the Feel Auto Mode press the Mode button until FEEL appears on the display In the Feel Auto Mode the fan speed and temperat...

Page 31: ...e hold the Eco button for 3 seconds Note The indoor blower works for some time and Indoor unit display will show after the AC is switched off to dry the indoor unit the unit will switch off thereafter...

Page 32: ...le to reach every part of the room Do not install the indoor unit near a source of heat steam or flammable gas Install the indoor unit near an electric socket or private circuit Do not install the ind...

Page 33: ...o that they remain fastened for years without becoming loose Do not install the outdoor unit near sources of heat steam or flammable gas Do not install the outdoor unit in windy or dusty places Do not...

Page 34: ...bove but the installation method is similar Drilling a hole in the wall for the piping Decide where to drill the hole in the wall for the piping if necessary according to the position of the mounting...

Page 35: ...n pipe and the power cables together with tape with the drain pipe at the bottom so that water can flow freely Shape the connection pipe Do not remove the cap from the pipe until connecting it to prev...

Page 36: ...nnection lag the pipe cables and drain pipe with the insulating material Arrange the pipes cables and drain hose well Lag the pipe joints with insulating material securing it with vinyl tape Run the b...

Page 37: ...ntion to the following Tighten the flare nuts using two wrenches Pay attention not to damage the pipes If the tightening torque is not sufficient there will probably be some leakage With excessive tig...

Page 38: ...nected pipe and cooling unit If this is not done the discharge pressure will rise abnormally and may damage the refrigerating cycle unit Remove the valve cap of the valve core Air purging using a vacu...

Page 39: ...is passed so that no air Or water can fill Note The electronic controller starts the compressor three minutes after voltage has reached the system Do ON OFF and fan operate normally Do the various mod...

Page 40: ...e with standard charge Maximum distance between indoor and outdoor unit Additional refrigerant charge Maximum difference in level between indoor and outdoor unit Type of refrigerant 3 8 9 52 1 2 12 7...

Page 41: ...ng diagram The wiring diagram may vary according to model Please check the wiring diagram under the front panel on the right hand side of the indoor unit as well as the back of the outdoor unit handle...

Page 42: ...mm 1 5 mm 1 5 mm 2 2 2 L 1 5 mm 1 5 mm 1 5 mm 2 2 2 1 5 mm 1 5 mm 1 5 mm 2 2 2 Connection supply N 1 5 mm 1 5 mm 1 5 mm cable 2 2 2 L 1 5 mm 1 5 mm 1 5 mm 2 2 2 1 1 5 mm 1 5 mm 1 5 mm 2 2 2 1 5 mm 1...

Page 43: ...ntroller for 12k 15k 18k 22k 24k 24k and 30k is rated 4A 250 V Type of fuse used on inverter outdoor unit controller for 12k is rated 15 A 250 V Type of fuse used on inverter outdoor unit controller f...

Page 44: ...Remove the batteries from remote control when the air conditioner is not in operation The remote control s batteries must be disposed off in accordance with the applicable laws in force in the countr...

Page 45: ...41 Applicable in selected models only...

Page 46: ...42...

Page 47: ...Switch it back ON once the power resumes Make sure there are no curtains blinds or furniture blocking the airflow Clean the filter every 2 weeks Refer Maintenance and cleaning After the air conditione...

Page 48: ..._____________ Service engineer to tick appropriately Air conditioner checked for damage Tapes removed from the front cover All packaging waste from customer s premises cleared with customer s prior pe...

Page 49: ...a smooth flow of drain water Use horizontal level gauge Downward Slope Do Not Raise Accumulated Drain Water Top of Drain Hose Dipped in Water Water Leakage Water Leakage Waving Water Leakage Air Ditch...

Page 50: ...and check for the following a Vibration abnormal noise heard Yes No b Electric power supply input volts and earthing for the unit 1 Voltmeter reading more than 100 mV and less than 3 V between N E Ye...

Page 51: ...DU will beep thrice Step 5 Change the set temp to 25 Deg C Step 6 Full load test setting will be activated IDU display will show FL Half Load 50 Capacity settings Step 1 By using remote controller tur...

Page 52: ...be provided on the outdoor PCB only During this extended warranty period IFB will repair replace the PCB Outdoor PCB Only which proves upon inspection by IFB or its authorized service franchisee to b...

Page 53: ...the air conditioner or by any external electrical supply thereof This includes failures due to erratic power supply fluctuations beyond rated voltage 10 voltage and frequency of 50 Hz 3 AC power suppl...

Page 54: ...t is subject to availability of parts from its manufacturers 12 IFB reserves the right to change add or delete any terms and conditions herein at any time without prior notice 13 The warranty shall be...

Reviews: