FAULT DIAGNOSIS
WHY DOES IT HAPPEN?
PILOT LAMP DOES NOT GLOW.
q
Check if the machine is ON.
q
Check for loose connections in plug/socket.
q
Check for blown fuse
WATER DOES NOT ENTER MACHINE/DETERGENT NOT
BEING FLUSHED INTO DRUM.
q
Check water supply
q
Porthole door not firmly closed
q
Water tap not turned on
q
Bent inlet hose
q
Sieve on inlet valve clogged
SUDS ESCAPING FROM DETERGENT DISPENSER TRAY.
q
Detergent used is not washing machine detergent
q
Excessive detergent used
q
Drain Line is blocked
WATER LEAKAGE FROM THE MACHINE
.
q
Inlet/Outlet hose connection loose
q
Fluff Filter not screwed on properly
q
Inlet hose leaking
MACHINE DOES NOT DRAIN
.
q
Fluff Filter clogged
q
Outlet hose end above 1 mtr. from floor level
MACHINE VIBRATES STRONGLY DURING SPINNING.
q
Machine not levelled properly
q
Clothes not loaded as instructed
q
Water not drained completely
MACHINE DOES NOT START.
q
Check position of programme selector knob
q
Check water supply
q
Porthole door not closed properly
q
Indicator lamp not glowing
MACHINE DOES NOT SPIN.
q
Check if the Spin Cancel Button is pressed.
MOTOR NOISE
q
It is normal for noises to be heard while motor is running. However
wash load, belt tension and motor mounting bolt should be
checked for specified limits.
PUMP NOISE
q
It is normal for noises to be heard from the pump during the start-up
and final stage of draining. However check for fluff filter clogging.
21
Summary of Contents for Executive Plus
Page 26: ...25...