background image

 

 

 

 

The informat ion  conta ined  in  th is docu ment is the property of  Automat ic  Syst ems and  is conf ident ial. The rec ip ient  is forb idd en to use  it for any purpose  ot her 
than  for  the  use  of  the  products  or  the  execut ion  of  the  project  to  wh ich  th ey  refer  or  to  commu nicate  it  to  th ird  parties  w ithout  the  pr ior  wr itten  conse nt  of 
Automat ic Systems. Document sub ject  to change w ithout advance not if icat ion .  

SL93x +  TBV327-MT-EN

 

p. 10/39 

 

 

 

Summary of Contents for AUTOMATIC SYSTEM PPV323

Page 1: ...the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 1 39 USER MANUAL Rev 10 Translated from French original notice GLASS SWING GATE SL930 SL931 SL932 PPV323 GLASS LOW HEIGHT TURNSTILE TBV327 ...

Page 2: ...tion device and suction mechanism by hold magnet Pages 15 34 translate electric diagrams in English 03 2010 06 11 Mfy RWK HB DL Complete revision for adaptation to the modification realized on the equipment 04 2010 07 01 Mfy Tec Spec replace flow by opening time of the obstacles Non return lock option for TBV only 05 2010 07 02 Mfy RH Installation Last points of the Fixing procedure transferred to...

Page 3: ...nt to the floor 11 3 4 Electrical connections 12 3 5 Commissioning 13 4 PRINCIPLE OF OPERATION 14 4 1 Locking 15 4 2 Position encoder 16 4 3 Safety 16 5 MAINTENANCE 17 5 1 Removing the housing 17 5 2 Turning the equipment ON OFF 18 5 3 Preventive maintenance 18 5 4 Spare parts 19 5 5 Adjusting the locking sensor 20 5 6 Adjusting the obstacle closed point 21 5 7 Setting the movement limit stops 5 p...

Page 4: ...atically without pushing the obstacle to avoid untimely out of order All operations on the equipment must be carried out by qualified personnel Any unauthorized operation or operation carried out by a technician not qualified on this product voids the manufacturer s guarantee automatically Access to the mechanism must be limited to personnel aware of the electrical and mechanical risks that are in...

Page 5: ...tion 0 50 A when turning 0 90 A while locking Automatic obstacle unlocking on power failure Variable speed controller ensures smooth obstacle movements Obstacle position determined by encoder Operating temperature 20 to 60 C Thanks to the heat generated by the powered internal equipment RH 95 without condensation Minimum opening time of the obstacle adjustable 2 5 seconds Net weight kg MCBF Mean C...

Page 6: ...fication SL93x PPV323 TBV327 MT EN p 6 39 2 2 Location of the components 1 Mounting base attached to the floor 2 Main chassis equipment without obstacle 3 Obstacle glass panel 4 Conical coupling of the rotor to the motor 5 Movement limit stop not on TBV 6 Variable speed controller 7 Locking system 8 Position encoder 9 Power supply board 10 Control board v16 CPU illustrated with optional IP module ...

Page 7: ...parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 7 39 3 INSTALLATION The installation must be carried out in accordance with the safety instructions p 4 and the installation plan p3 2 3 1 Storage Before installation avoid all shocks to the equipment and place it in its original packing in a dry place ...

Page 8: ... en to use it for any purpose other than for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 8 39 3 2 Installation plans ...

Page 9: ... is forbidd en to use it for any purpose other than for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 9 39 ...

Page 10: ... is forbidd en to use it for any purpose other than for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 10 39 ...

Page 11: ...It is essential to adapt the fastening hardware and the installation procedure to the environment and the nature of the floor on which the gate will be positioned Installation must be validated by certified civil engineers The gate must be fastened to the floor before it is made available to the users Automatic Systems cannot be held responsible for any accident or damage to the gate due to the fa...

Page 12: ... begun Connections must be executed in accordance with the wiring diagrams provided inside the equipment which remain the reference Type of cable Connections 3G2 5 Electrical power supply of each equipment 230 V single phase ground differential breaker 30 mA min for each equipment WARNING High leakage current Connection to the ground imperative with a 1 mm cable before connecting the mains Do not ...

Page 13: ...echanical stops ch 5 7 2 Switch ON the equipment The obstacle will move seeking its starting point closed position then it locks 3 Start the CONFIG AUTO menu Note the obstacles must be fitted Press the Menu button Press the button until CONFIG AUTO is displayed Press OK to start the procedure The equipment seeks the mechanical stops in both directions at slow speed and accelerates 4 Check the lock...

Page 14: ...tacles 3 The gate is unlocked by an external command pushbutton card readers etc According to the selected mode the obstacle then starts to turn automatically in the authorized direction of passage or on light pressure The movement of the obstacle is transmitted by a geared motor driven by a variable speed controller 6 which allows the opening and closing speed to be adjusted The opening angle can...

Page 15: ...activated by detection of a vane 76 The electromagnet then moves the lock into hole 77a of plate 77 locking the rotor 12 Locking is maintained by the electrical circuit between the hold magnet 72 and the contact plate 73 The Fire Detection signal on the power board see wiring diagrams opens the obstacle in the selected direction and allows free passage NON RETURN OPTION for TBV model only During t...

Page 16: ...nd passes through 2 sensors 81 and 82 This encoder does not need any adjustment 4 3 Safety During rotation if the obstacle encounters an obstruction limiting its movement it will make several attempts to complete the current movement after which the motor will be powered off automatically if the resistance is still present see parameter NUMBER OF WARNINGS ch 5 10 As long as the opening command is ...

Page 17: ...project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 17 39 5 MAINTENANCE WARNING The adjustment operations must be carried out in accordance with the safety instructions p 4 5 1 Removing the housing 1 Remove all the screws 50 2 Remove both element...

Page 18: ...st check the following points The security of all components attachment to the floor obstacle motor conical coupling 4 p 6 etc The state of the ground cable on the rotor Fig A The control signals The opening and closing speeds The obstacle opening and closing angles and positions The activation of the locking mechanism in the closed position The unlocking in case of a power outage The obstacle ope...

Page 19: ...m OBV E07047 01 2007 x Mobile obstacle 1230 x 850 mm OBV E07050 01 2007 x Mobile obstacle 1530 x 850 mm OBV E07030 01 2007 x Mobile obstacle 1730 x 850 mm OBV E07049 01 2007 x Mobile obstacle 480 x 640 mm OBV E07054 01 2007 x Mobile obstacle 640 x 950 mm OBV E07052 01 2007 x Mobile obstacle 830 x 850 mm OBV E07014 01 2007 x Motor assembly with encoder 14 8 p6 0 6982 065 12 2008 x x x x x Motor ass...

Page 20: ... Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 20 39 5 5 Adjusting the locking sensor 1 Unlock the obstacle by switching off the power or selecting programming mode 2 Turn rotor 12 until one of the 3 locking holes is in front of lock 70 3 In that position the sensor 75 must detect one of the vanes 76 If necessary adjust the vane and or the va...

Page 21: ...arts of the coupling are separated Note if the screws E are not supplied use 3 screws D 4 Move the obstacle to its closed position 5 Unscrew the 3 screws E and tighten the other 6 D 5 7 Setting the movement limit stops 5 p6 Note there are no stops for the TBV327turnstile Note Check that the obstacle operating angle allowed by the stops is greater than the angle set by the OPENING ANGLE CLOCKWISE a...

Page 22: ...PV323 TBV327 MT EN p 22 39 5 8 Fitting and adjusting the locking mechanism a Slacken the lock nut 36 and screw the lock 21 completely onto the threaded rod 22 b Unscrew 4 turns Unscrew the sleeve 23 pass the rod through the plate and tighten the sleeve Turn the obstacle rotor 12 p6 so that the lock 21 lines up with a locking hole cf ch 5 5 Turn the sleeve 23 until it is 9 mm above the plate level ...

Page 23: ... which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 23 39 Fit the electromagnet assembly to plate 28 by means of screw 29 Put the fixing screws 30 in place without tightening them Push in the electromagnet core 31 to bring the centre shaft 32 in contact wi...

Page 24: ...ve the complete lock assembly away from the frame Fix the lock assembly to the plate by tightening screws 30 In the locked position activate the lock by pushing core 31 and not contact plate 34 adjust the lock 21 until it is as far as possible into the hole the contact plate 34 must smoothly lie on hold magnet 35 without forcing If not the case adjust the hold magnet support height by means of the...

Page 25: ...ion SL93x PPV323 TBV327 MT EN p 25 39 5 9 Replacing an obstacle 1 Remove the 2 parts of the housing by unscrewing the screws 50 2 Hold the glass plate 3 Remove the screws 51 maintaining the glass on its support 4 Remove the clamp 52 5 Remove the glass plate 6 Remove the spacers 53 from the holes in the glass plate that has been removed and fit them to the new glass plate 7 Attach the new glass pla...

Page 26: ...ion of the obstacle with regard to its closed position Serial n of the CPU board alternating with the IP address of the board if the IP interface option is fitted The obstacle rotation speed Any error messages ch 5 12 Enter the menu by pressing the center button MENU the obstacle unlocks Note do not enter the menu before the serial n is displayed This would lose the customized configuration and re...

Page 27: ...ection This adjustment may be necessary according to obstacle s height Note adjust the limit stops after modifying this parameter ch 5 7 OPENING ANGLE B WAY PPV only Fine adjustment of the maximum opening angle in the counter clockwise direction B direction measured during the automatic configuration AUTOMATIC SETUP section This adjustment may be necessary according to obstacle s height Note adjus...

Page 28: ...s Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 28 39 Parameter Description AUTOMATIC SETUP Automatic configuration of the BRAKING ANGLE according to the ROTATION SPEED set and the obstacle inertia PRESS OK TO QUIT AND SAVE SETUP Leave programming mode and return to the main screen MANUFACTURER RESET Loading of the default values for the menu and the variable ...

Page 29: ... 39 5 11 Maintenance interface 5 11 1 Network communication settings Note a basic knowledge of networks is necessary 1 Switch the power on the gate ch 5 2 2 Connect a PC to the RJ45 connector of the CPU board by means of an Ethernet patch cable 3 Set the PC communication parameters On the web browser deactivate the Network communication mode via Proxy server Set the PC IP address to be in the same...

Page 30: ...umber of major minor defects since the last reset Number of openings in clockwise direction A or counter clockwise B since the last reset Same counters as above without reset Reset of 1 of the 4 counters above Mechanical play of the motor coupling Last minor defect registered Last major defect registered Indicate the type of gate see serial number or installation drawing Note if the gate is connec...

Page 31: ...nt of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 31 39 5 11 6 Network 5 11 7 Menu Configuration Modification of the gate s IP address cf ch 5 11 1 to adapt it to a new network These parameters must be authorized by the network manager Note the gate s IP address is displayed on the CPU when powering it on Validation of the modifications Thi...

Page 32: ...speed and opening angles ch 5 10 These must be smaller than the angles allowed by the mechanical stops Mot drive com communication fault with the variable speed controller Lock fever fuse failed on the lock electro magnet Emergency opening Emergency FIRE opening active on the power supply board Note The error is reset by an opening command or an Emergency opening command The obstacle does not move...

Page 33: ...or written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 33 39 5 13 Disposal Destruction If the equipment is not used for an extended period it should be stored in a dry place protected from heat and bad weather conditions When the equipment is retired from service dispose of the various components through the appropriate channels ...

Page 34: ...SL93x PPV323 TBV327 MT EN p 34 39 6 ELECTRICAL DIAGRAMS NEUTRAL LINE MAINS 220V AC VARIABLE SPEED CONTROLLER 220V 220V GROUND MOTOR SC S5 S4 S3 S2 S1 U V W R R SG S S Locking position sensor Motor encoder sensors Hold magnet Electromagnet Non return lock option thermal fuse Ground connector 10 2012 CPU V16 PWR board V10 ground contact plate HOUSING Voltage Dry contacts 24 Vdc or 48 Vdc see above O...

Page 35: ... is forbidd en to use it for any purpose other than for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 35 39 ...

Page 36: ... the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 36 39 GATE OPEN except for emergency cmd COUNTERCLOCKWISE opening request RS 485 07 08 09 10 11 12 13 14 15 16 17 18 except for emergency cmd DEFECT DETECTED CLOSED LOCKED GATE CLOCKWISE op...

Page 37: ...of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 37 39 DOUBLE GATES In the case of 2 gates that must open simultaneously one opens in the clockwise direction and the other in the anti clockwise direction and vice versa Note The opening request inputs must be connected as described below Note that the clockwise input on one gate is connected t...

Page 38: ... to use it for any purpose other than for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 38 39 7 DECLARATION OF CONFORMITY ...

Page 39: ... for the use of the products or the execution of the project to which they refer or to commu nicate it to third parties without the prior written consent of Automatic Systems Document subject to change without advance notification SL93x PPV323 TBV327 MT EN p 39 39 AUTOMATIC SYSTEMS BELGIUM HQ Email asmail automatic systems com Tel 32 10 23 02 11 Fax 32 10 23 02 02 ...

Reviews:

Related manuals for AUTOMATIC SYSTEM PPV323