TANK-XM811
Page 37
3.13
Maintenance
To configure the jumper settings, please follow the steps below.
Step 1:
Remove the top cover. See Figure 3-2.
Step 2:
Locate the jumper on the embedded motherboard.
Step 3:
Make the jumper settings in accordance with the settings described and
defined in the following sections.
3.13.1
Flash Descriptor Security Override Jumper
The Descriptor Security Override jumper (J_FLASH1) allows users to enable or disable
the ME firmware update. Refer to Figure 3-25 and Table 3-5 for the jumper location and
settings.
Setting
Description
Short 1-2
Disabled (default)
Short 2-3
Enabled
Table 3-5: Flash Descriptor Security Override Jumper Settings
Figure 3-25 Flash Descriptor Security Override Jumper Location
To update the ME firmware, please follow the steps below.