![IEI Technology NOVA-300 Manual Download Page 22](http://html1.mh-extra.com/html/iei-technology/nova-300/nova-300_manual_4098240022.webp)
22
All the items on the left side of the screen are very common,
they will not be mentioned here. Here, we just focus on some
special items which are in NOVA-300 board only. These items
are specified as following :
¡ E
On-board IDE Controller : The IDE hard disk drive can be
Enable
or
Disable
by this item. When you do not
need hard disk, the IDE controller can be disabled.
¡ E
On-board Floppy Controller : The floppy disk drive can be
Enable
or
Disable
by this item. When you do not
need floppy disk, the FDD controller can be
disabled.
¡ E
Serial Port 1 : default at 3E8 and IRQ11.
¡ E
Serial Port 2 : default at 2E8 and IRQ10 or set as IR function.
¡ E
Serial Port 3 : default at 3F8 and IRQ4.
¡ E
Serial Port 4 : default at 2F8 and IRQ3.
¡ E
Parallel Port : The options are
Disable
,
3BC
,
378
or
278
. You
can set the I/O address of the parallel port or
disable it.
¡ E
Parallel Port Mode : NOVA-300 provides
EPP,ECP,ECP+EPP,
and
Normal Mode.
Primary Display : You could set
VGA/EGA, CGA40x25,
CGA80x25, Mono or Absent
. When set
Absent the NOVA-300 will not check the
display adapter when power on the system.
System Keyboard : You could set
Present
or
Absent
.
When set Absent the NOVA-300 will not
check the display adapter when power on
the system.
Appendix A. E
2
Key™
Function
The NOVA-300 provides an outstanding E
2
KEY™
function for
system integrator. Based on the E
2
KEY™
you could free to store