4.3.5 Power Management
Use the
Power Management
menu (
) to configure the power management
function.
Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.
Advanced
Current Voltage
: +12.0 V
Low Voltage Warning
[9V]
*** Delay Time Setting ***
Auto Power On Delay
[10 sec]
Auto Power Off Delay
[20 sec]
Set Low Voltage Warning
(8V~37V)
---------------------
: Select Screen
↑
↓
: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Version 2.18.1263. Copyright (C) 2017 American Megatrends, Inc.
BIOS Menu 9: Power Management
Low Voltage Warning [9V]
Use the
Low Voltage Warning
option to set the low voltage warning from 8V to 37V. If the
system voltage is lower than the value set here, the power LED on the system front panel
will blink at regular intervals (refer to
Section 1.5.1
) to warn users.
Auto Power On Delay [10 sec]
Use the
Auto Power On Delay
option to set the automatic power-on delay time.
Configuration options are listed below.
10 sec
D
EFAULT
30 sec
1 min
5 min
10 min
15 min
30 min
Summary of Contents for IVS-110
Page 14: ......
Page 15: ...IVS 110 Embedded System Page 1 Chapter 1 1 Introduction ...
Page 24: ...IVS 110 Embedded System Page 10 Chapter 2 2 Unpacking ...
Page 28: ...IVS 110 Embedded System Page 14 Chapter 3 3 Installation ...
Page 53: ...IVS 110 Embedded System Page 39 Chapter 4 4 BIOS ...
Page 91: ...IVS 110 Embedded System Page 77 Chapter 5 5 Troubleshooting and Maintenance ...
Page 95: ...IVS 110 Embedded System Page 81 Chapter 6 6 Interface Connectors ...
Page 100: ...IVS 110 Embedded System Page 86 Appendix A A Regulatory Compliance ...
Page 105: ...IVS 110 Embedded System Page 91 B Safety Precautions Appendix B ...
Page 111: ...IVS 110 Embedded System Page 97 Appendix C C BIOS Menu Options ...
Page 114: ...IVS 110 Embedded System Page 100 Appendix D D Watchdog Timer ...
Page 117: ...IVS 110 Embedded System Page 103 Appendix E E Hazardous Materials Disclosure ...